Inferior vena cava diameters and collapsibility index reveal early volume depletion in a blood donor model
Open Access
- 4 November 2015
- journal article
- research article
- Published by Springer Nature in The Ultrasound Journal
- Vol. 7 (1) , 1-7
Abstract
Changes of volume status can be readily inferred from variations in diameter of the inferior vena cava (IVC) measured by ultrasound. However the effect of IVC changes following acute blood loss are not fully established. In this study, three different approaches to measuring IVC variables were compared in healthy blood donors, as a model of acute volume depletion, in order to establish their relative ability to detect acute blood loss. Inspiratory and expiratory IVC diameters were measured before and after blood donation in hepatic long axis, hepatic short axis and renal short axis views using a 2–5 MHz curvilinear probe. All measurements were recorded and examined in real-time and post-processing sessions. All windows performed satisfactorily but the renal window approach was feasible in only 30 out of 47 subjects. After blood donation, IVC diameters decreased in hepatic long axis, hepatic short axis and renal short axis (expiratory: −19.9, −18.0, −26.5 %; CI 95 %: 14.5–24.1; 13.1–22.9; 16.0–35.9, respectively) (inspiratory: −31.1, −31.6, −36.5 %; CI 95 %: 21.3–40.1; 18.8–45.2; 23.4–46.0, respectively), whereas the IVC collapsibility index increased by 21.6, 22.6 and 19.3 % (CI 95 %: 11.6–42.9; 18.5–39.5; 7.7–30.0). IVC diameters appeared to return to pre-donation values within 20 min but this was only detected by the hepatic long axis view. IVC diameter and collapsibility index variations, as measured in M mode, consistently detect volume changes after blood donation. The longitudinal mid-hepatic approach performed better by allowing a panoramic view, avoiding anatomical aberrancies at fixed points and permitting to identify the best possible perpendicular plane to the IVC. In addition, it was able to detect time-dependent physiological volume replacement. In contrast, in our hands, the renal window could not be visualized consistently well.Keywords
This publication has 21 references indexed in Scilit:
- Inferior vena cava displacement during respirophasic ultrasound imagingThe Ultrasound Journal, 2012
- Ultrasound Does Not Detect Early Blood Loss in Healthy Volunteers Donating BloodThe Journal of Emergency Medicine, 2011
- The Interrater Reliability of Inferior Vena Cava Ultrasound by Bedside Clinician Sonographers in Emergency Department PatientsAcademic Emergency Medicine, 2011
- Inferior Vena Cava Percentage Collapse During Respiration Is Affected by the Sampling Location: An Ultrasound Study in Healthy VolunteersAcademic Emergency Medicine, 2010
- Identification of congestive heart failure via respiratory variation of inferior vena cava diameterThe American Journal of Emergency Medicine, 2009
- Intensivist Bedside Ultrasound (INBU) for Volume Assessment in the Intensive Care Unit: A Pilot StudyJournal of Trauma: Injury, Infection & Critical Care, 2007
- Reappraisal of the Use of Inferior Vena Cava for Estimating Right Atrial PressureJournal of the American Society of Echocardiography, 2007
- Handcarried Ultrasound Measurement of the Inferior Vena Cava for Assessment of Intravascular Volume Status in the Outpatient Hemodialysis ClinicClinical Journal of the American Society of Nephrology, 2006
- Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cavaThe American Journal of Cardiology, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986