Pachymetric mapping with Fourier-domain optical coherence tomography
Authors:
- 1 May 2010
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 36 (5) , 826-831
Abstract
To evaluate the repeatability of Fourier-domain optical coherence tomography (OCT) pachymetric mapping and compare central corneal thickness (CCT) measurements by OCT, ultrasound pachymetry, and scanning-slit tomography. Doheny Eye Institute, University of Southern California, Los Angeles, California, USA. A Fourier-domain OCT system was used to map the corneal thickness in normal eyes with scans centered on the corneal vertex or the pupil. Repeatability of central and pericentral map sectors was assessed by pooled standard deviation. The CCT measurements were compared between the OCT, ultrasound, and scanning-slit devices. Pupil centration (SD: 1.3 microm central, 1.8 to 3.8 microm pericentral) provided better repeatability than vertex centration (SD: 1.7 microm central, 2.4 to 5.7 microm pericentral) in all sectors (P<.035). The mean CCT was 536.9 microm +/- 27.0 (SD) by OCT, 556.6 +/- 30.5 microm by ultrasound, and 537.2 +/- 32.6 microm by scanning-slit tomography (acoustic factor 0.92). The CCT measured by OCT was significantly thinner than by ultrasound pachymetry (P = .007; mean difference -19.7 microm; 95% limits of agreement [LoA], -40.4 to 0.9 microm) but not than by scanning-slit tomography (P = .2637; mean difference -0.3 microm; 95% LoA, -24.0 to 23.5 microm). The CCT by OCT correlated well with ultrasound and scanning-slit CCTs (r = 0.940 and r = 0.934, respectively). Pachymetric mapping with Fourier-domain OCT was highly repeatable. Repeatability was better with pupil-centered scans than with corneal vertex-centered scans. Ultrasound pachymetry, Fourier-domain OCT, and scanning-slit tomography should not be used interchangeably for CCT assessment.Keywords
This publication has 23 references indexed in Scilit:
- Keratoconus Diagnosis with Optical Coherence Tomography Pachymetry MappingOphthalmology, 2008
- Repeatability and Reproducibility of Pachymetric Mapping with Visante Anterior Segment–Optical Coherence TomographyInvestigative Ophthalmology & Visual Science, 2007
- Central corneal thickness measurement with Pentacam, Orbscan II, and ultrasound devices before and after laser refractive surgery for myopiaJournal of Cataract & Refractive Surgery, 2007
- In Vivo Corneal High-Speed, Ultra–High-Resolution Optical Coherence TomographyArchives of Ophthalmology (1950), 2007
- High-speed Optical Coherence Tomography of Corneal OpacitiesOphthalmology, 2007
- Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopiaJournal of Cataract & Refractive Surgery, 2007
- Corneal Pachymetry Mapping with High-speed Optical Coherence TomographyOphthalmology, 2006
- Three-dimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segmentsOptics Express, 2005
- Characteristics of Keratoconus and Pellucid Marginal Degeneration in Mean Curvature MapsAmerican Journal of Ophthalmology, 2005
- Central corneal thickness measurements with partial coherence interferometry, ultrasound, and the Orbscan systemOphthalmology, 2004