LC–MS/MS separation and quantitation of ribavirin in chicken and comparison of different mass spectrometric platforms
Authors:
Open Access
- 7 August 2023
- journal article
- research article
- Published by Springer Nature in BMC Chemistry
- Vol. 17 (1) , 1-10
Abstract
A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed for the analysis of ribavirin in chicken. Samples was extracted with 0.1% formic acid and purified by Hypercarb cartridge prior to LC–MS/MS analysis. The eluates were evaporated to dryness, reconstituted in 1 mL 5mM ammonium acetate containing 5% acetonitrile (v/v) and 0.1% (v/v) formic acid. Chromatographic separation was performed on a Hypercarb analytical column under a gradient elution program with acetonitrile and 0.1% (v/v) formic acid in 5 mM ammonium acetate at a flow rate of 0.6 ml/min. The intraday and interday accuracy ranged from − 7.83 − 1.39%, and − 6.38 − 2.25%, with precisions between 1.34 − 3.88%% and 1.10 − 4.67%. The limits of detection (LODs) and limits of quantitation (LOQs) of ribavirin was 0.1 ng/mL and 0.5 ng/mL, respectively. The method was validated for linearity, accuracy, precision, matrix effect and stability. Application of the method confirmed 3 ribavirin positive samples out of 50 commercial chicken samples, with concentrations of ribavirin ranging from 0.9 μg/kg to 5.8 μg/kg a, respectively. Additionally, both AB Sciex 5500 and Agilent 6945B were proven to be suitable in ribavirin separation and quantification. The described method is suitable for the determination of ribavirin in chicken in analytical practice to monitor illegal addition of this kind of anti–viral drug.Keywords
Funding Information
- Key Science and Technology Program of Market Supervision Administration of Nanjing (Kj2019045, Kj2019045, Kj2019045, Kj2019045, Kj2019045)
This publication has 41 references indexed in Scilit:
- Matrix effects break the LC behavior rule for analytes in LC-MS/MS analysis of biological samplesExperimental Biology and Medicine, 2014
- Application of nanoring amino-functionalized magnetic polymer dispersive micro-solid-phase extraction and ultra fast liquid chromatography–tandem mass spectrometry in dicyandiamide residue analysis of powdered milkTalanta, 2014
- Determination of amantadine and rimantadine in chicken muscle by QuEChERS pretreatment method and UHPLC coupled with LTQ Orbitrap mass spectrometryJournal of Chromatography B, 2013
- Aqueous normal phase liquid chromatography coupled with tandem time-of-flight quadrupole mass spectrometry for determination of zanamivir in human serumJournal of Chromatography B, 2012
- Development and validation of a useful HPLC–UV method for quantification of total and phosphorylated-ribavirin in blood and erythrocytes of HCV+ patientsJournal of Pharmaceutical and Biomedical Analysis, 2012
- Determination of ribavirin in human serum using liquid chromatography tandem mass spectrometryTalanta, 2012
- Hydrophilic interaction liquid chromatography coupled to mass spectrometry for the characterization of prebiotic galactooligosaccharidesJournal of Chromatography A, 2012
- LC–MS/MS quantitation of ribavirin in serum and identification of endogenous isobaric interferencesClinica Chimica Acta, 2011
- Evaluation Conditions for SFC of Metoprolol and Related Amino Alcohols on Hypercarb (Porous Graphitic Carbon) with Respect to Structure–Selectivity RelationsChromatographia, 2009
- Simultaneous determination of ribavirin and ribavirin base in monkey plasma by high performance liquid chromatography with tandem mass spectrometryJournal of Chromatography B, 2007