Agreement Between a Wireless Sleeve and a Goniometer in Measuring Elbow and Knee Range of Motion
Open Access
- 6 September 2025
- journal article
- Published by Springer Nature in Cureus
- Vol. 17 (9)
Abstract
Introduction Goniometers are a common clinical tool for measuring joint range of motion. Wearable sleeves offer a novel and alternative method to measure joint angles, record range of motion (ROM), and remotely track changes in ROM over time. Additionally, they may aid in the surgical planning required for deformity correction. This investigation compared the reliability and validity of a conventional goniometer to a novel transducer-embedded sleeve when measuring flexion and extension of the elbow and knee. Methods This was a cross-sectional study of 55 patients (110 elbows, 110 knees) who donned an elbow and knee sleeve embedded with a gallium-based strain sensor. Flexion and extension of the elbow and knee were measured both manually using a goniometer and a wearable sleeve. Agreement between the two devices was assessed via Bland-Altman plots. Results Regarding elbow flexion, the bias observed between the two devices was 4.6° with LoA spanning from -14.9° to 24.1°. Regarding elbow extension, the bias observed between the two devices was -9.8° with LoA spanning from -25.6° to 6.0°. Regarding knee flexion, the bias observed between the two devices was -4.6° with LoA spanning from -35.6° to 26.4°. Regarding knee extension, the bias observed between the two devices was -2.8° with LoA spanning from -8.9° to 3.3°. Conclusion Wearable sleeves show promise for clinical ROM measurement and remote monitoring but require further refinement to reduce bias before clinical application.Keywords
This publication has 17 references indexed in Scilit:
- Validity of wearable sensors for total knee arthroplasty (TKA) rehabilitation: A study in younger and older healthy participantsThe Knee, 2024
- Inclinometers and Apps Are Better than Goniometers, Measuring Knee Extension Range of Motion in Anterior Cruciate Ligament Patients: Reliability and Minimal Detectable Change for the Three DevicesThe Journal of Knee Surgery, 2024
- “Wearable Sensors to Guide Remote Rehabilitation Following Knee Arthroplasty Surgery”Indian Journal of Orthopaedics, 2022
- Direct Wiring of Liquid Metal on an Ultrasoft Substrate Using a Polyvinyl Alcohol Lift-off MethodACS Applied Materials & Interfaces, 2022
- Smart Technology and Orthopaedic Surgery: Current Concepts Regarding the Impact of Smartphones and Wearable Technology on Our Patients and PracticeCurrent Reviews in Musculoskeletal Medicine, 2021
- Reliability, Concurrent Validity, and Minimal Detectable Change for iPhone Goniometer App in Assessing Knee Range of MotionThe Journal of Knee Surgery, 2016
- Factors Influencing the Reliability of the Universal Goniometer in Measurement of Lower-Limb Range of MotionJPO Journal of Prosthetics and Orthotics, 2015
- Comparison of measurement accuracy between two wrist goniometer systems during pronation and supinationJournal of Electromyography and Kinesiology, 2002
- Reliability of range-of-motion measurement in the elbow and forearmJournal of Shoulder and Elbow Surgery, 1998
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986