Method for Quantification of a Prostate Cancer Biomarker in Urine without Sample Preparation
Authors:
- 15 September 2007
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (20) , 7683-7690
Abstract
We describe a macrocantilever-based method for detecting a prostate cancer biomarker (alpha-methylacyl-CoA racemase; AMACR) directly in patient urine without a sample preparation step and without the use of labeled reagents. Clean catch voided urine specimens were prospectively collected from five confirmed prostate cancer patients 3 weeks postbiopsy. The presence of AMACR was measured in a blinded manner by exposing 3 mL of urine to the anti-AMACR-immobilized piezoelectric-excited millimeter-sized (PEMC) sensor. The resonance frequency of PEMC decreases as AMACR from sample binds to the antibody on the sensor. The resonance frequency changes for the five patients tested were 4,314 +/- 35 (n = 2), 269 +/- 17 (n = 2), 977 +/- 64 (n = 3), 600 +/- 31 (n = 2), and 801 +/- 81 (n = 2) Hz, respectively. Positive detection was observed within approximately 15 min. The responses to positive, negative, and buffer controls were -9 +/- 13, -34 +/- 18, and -6 +/- 18 Hz, respectively. Positive verification of AMACR attachment was confirmed by low-pH buffer release. The sensor response was quantitatively related to AMACR concentration in control urine, and the relationship was used in developing an in situ calibration method for quantifying AMACR in patient urine. Estimated concentrations of 42, 2, and 3 fg/mL AMACR were calculated for the three patients' urine, while absence of AMACR was confirmed in control urine (n = 13). Because of simplicity of measurement combined with high sensitivity and specificity, the method may be a useful adjunct in a point-of-care setting to identify men at increased risk for prostate cancer.Keywords
This publication has 21 references indexed in Scilit:
- Detection of prostate cancer by α‐methylacyl CoA racemase (P504S) in needle biopsy specimens previously reported as negative for malignancyHistopathology, 2006
- Proteomic Analysis of Serum Associated Fucosylated Glycoproteins in the Development of Primary Hepatocellular CarcinomaJournal of Proteome Research, 2006
- Ultra-Sensitive Immunoassays Using Multi-Photon-Detection in Diagnostic Proteomics of BloodJournal of Proteome Research, 2005
- PROSTATE CANCER DETECTION ON URINALYSIS FOR α METHYLACYL COENZYME A RACEMASE PROTEINJournal of Urology, 2004
- Humoral Immune Response to -Methylacyl-CoA Racemase and Prostate CancerJNCI: Journal of the National Cancer Institute, 2004
- Screening Men for Prostate and Colorectal Cancer in the United StatesJAMA, 2003
- α-Methylacyl-CoA Racemase: Expression Levels of this Novel Cancer Biomarker Depend on Tumor DifferentiationThe American Journal of Pathology, 2002
- P504S/α-Methylacyl-CoA RacemaseAmerican Journal of Surgical Pathology, 2002
- Delineation of prognostic biomarkers in prostate cancerNature, 2001
- Comparison of Digital Rectal Examination and Serum Prostate Specific Antigen in the Early Detection of Prostate Cancer: Results of a Multicenter Clinical Trial of 6,630 MenJournal of Urology, 1994