A Robust Method for Estimating Respiratory Flow Using Tracheal Sounds Entropy
Authors:
- A. YadollahiAYA. Yadollahi
- Z.M.K. MoussaviZMZ.M.K. Moussavi
- 20 March 2006
- journal article
- clinical trial
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 53 (4) , 662-668
Abstract
The relationship between respiratory sounds and flow is of great interest for researchers and physicians due to its diagnostic potentials. Due to difficulties and inaccuracy of most of the flow measurement techniques, several researchers have attempted to estimate flow from respiratory sounds. However, all of the proposed methods heavily depend on the availability of different rates of flow for calibrating the model, which makes their use limited by a large degree. In this paper, a robust and novel method for estimating flow using entropy of the band pass filtered tracheal sounds is proposed. The proposed method is novel in terms of being independent of the flow rate chosen for calibration; it requires only one breath for calibration and can estimate any flow rate even out of the range of calibration flow. After removing the effects of heart sounds (which distort the low-frequency components of tracheal sounds) on the calculated entropy of the tracheal sounds, the performance of the method at different frequency ranges were investigated. Also, the performance of the proposed method was tested using 6 different segment sizes for entropy calculation and the best segment sizes during inspiration and expiration were found. The method was tested on data of 10 healthy subjects at five different flow rates. The overall estimation error was found to be 8.3 /spl plusmn/ 2.8% and 9.6 /spl plusmn/ 2.8% for inspiration and expiration phases, respectively.Keywords
This publication has 24 references indexed in Scilit:
- A Robust Method for Heart Sounds Localization Using Lung Sounds EntropyIEEE Transactions on Biomedical Engineering, 2006
- Recursive least squares adaptive noise cancellation filtering for heart sound reduction in lung sounds recordings2004
- Heart sound cancellation from lung sound recordings using adaptive threshold and 2D interpolation in time-frequency domain2004
- Phonospirometry for noninvasive measurement of ventilation: methodology and preliminary resultsJournal of Applied Physiology, 2002
- The Relationship between Normal Lung Sounds, Age, and GenderAmerican Journal of Respiratory and Critical Care Medicine, 2000
- Adaptive reduction of heart sounds from lung sounds using fourth-order statisticsIEEE Transactions on Biomedical Engineering, 1997
- Spectral characteristics of chest wall breath sounds in normal subjects.Thorax, 1995
- Repeatability of Measurements of Normal Lung SoundsAmerican Journal of Respiratory and Critical Care Medicine, 1994
- Intraction between tracheal sound and flow rate: a comparison of some different flow evaluations from lung soundsIEEE Transactions on Biomedical Engineering, 1990
- Distinguishing normal and abnormal tracheal breathing sounds by principal component analysis.The Japanese Journal of Physiology, 1990