Reproducibility of ductus venosus Doppler flow measurements at 11–14 weeks of gestation
Authors:
- 1 April 2001
- journal article
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 17 (4) , 301-305
Abstract
To assess the intra- and interobserver repeatabilities of fetal ductus venosus Doppler measurements at 11-14 weeks of gestation.Flow velocity waveforms were recorded transabdominally. Intraobserver repeatability was studied in 22 fetuses in whom four repeated measurements were performed by the same observer. Interobserver repeatability was assessed in 54 fetuses in each of whom two observers performed two repeated measurements. The pulsatility index for veins (PIV), peak velocity during ventricular systole (S wave), peak velocity during atrial contraction (A wave) and time-averaged maximum velocity (TAMV) were recorded. Reproducibility of the Doppler measurements was analyzed by calculating repeatability coefficient, coefficient of variation (CV), intraclass correlation coefficient (ICC), mean differences and their limits of agreement. Cohen's k-coefficient was used for categorical data.Intraobserver repeatability was good with a CV of 10%, 13%, 22% and 13% and an ICC of 0.85, 0.94, 0.94 and 0.95, respectively, for PIV, S wave, A wave and TAMV. Interobserver repeatability was also good, and no bias between the observers was detected. A CV of 8.8%, 14%, 27% and 15% and an ICC of 0.86, 0.84, 0.87 and 0.84, respectively, for PIV, S wave, A wave and TAMV were obtained. There was 100% agreement for the detection of normal/abnormal blood flow.Intra- and interobserver repeatability of all parameters was acceptable, allowing for the detection of moderate to large changes in Doppler measurements.Keywords
This publication has 18 references indexed in Scilit:
- Cardiac defects in chromosomally normal fetuses with abnormal ductus venosus blood flow at 10–14 weeksUltrasound in Obstetrics & Gynecology, 1999
- Nuchal translucency, ductus venosus and congenital heart disease: an important association – a cautious analysisUltrasound in Obstetrics & Gynecology, 1999
- Screening for chromosomal abnormalities at 10–14 weeks: the role of ductus venosus blood flowUltrasound in Obstetrics & Gynecology, 1998
- Reproducibility of transvaginal Doppler velocimetry measurements in the uterine arteries of postmenopausal womenUltrasound in Obstetrics & Gynecology, 1997
- Cardiotocogram compared to Doppler investigation of the fetal circulation in the premature growth‐retarded fetus: longitudinal observationsUltrasound in Obstetrics & Gynecology, 1997
- Fetal venous, intracardiac, and arterial blood flow measurements in intrauterine growth retardation: Relationship with fetal blood gasesAmerican Journal of Obstetrics and Gynecology, 1995
- Reproducibility of Doppler blood flow velocity measurements in the uterine and ovarian arteries of postmenopausal womenEuropean Journal of Ultrasound, 1995
- Doppler flow velocity waveforms in late first‐ and early second‐trimester fetuses: reproducibility of waveform recordingsUltrasound in Obstetrics & Gynecology, 1993
- Intra‐observer and inter‐observer reliability of the pulsatility index calculated from pulsed Doppler flow velocity waveforms in three fetal vesselsBJOG: An International Journal of Obstetrics & Gynaecology, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986