Does introduction of a cemented polished taper-slip femoral stem reduce early periprosthetic fracture risk with anterior approach total hip arthroplasty? A case-matched study
- 24 April 2025
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-11
Abstract
Background Anterior approach total hip replacement (AA-THA) is associated with higher periprosthetic fracture (PFF) risk. Cemented femoral fixation may reduce this risk. This study aims to (1) determine if using a cemented polished taper-slip (PTS) stem reduces PFF risk, (2) describe perioperative complications, and (3) identify factors associated with outcome. Methods This was a retrospective, case-matched cohort study from an academic center. The first 122 hybrid AA-THAs with a minimum 12-month follow-up were reviewed. These were matched (1:2) for age, sex, BMI, femoral and pelvic morphology with 244 AA-THAs using an uncemented, short, stem. Outcomes measured include PPF (Vancouver classification) rate, reoperation rate, complications, cement quality, and radiologic measurements. Results Nineteen PFFs (5.2%) occurred at a mean 14.5±23 days following surgery. There was no difference in PPF rate between groups (Cemented Stems: 7/122, 5.7%, 5/7 Type-A and 2/7 Type-B2; Uncemented Stems: 12/244, 4.9%, 7/12 Type-A, 4/12 Type-B2 and 1/12 Type-C; p = 0.847). There was no difference in PPF risk between short (≤ 125 mm) and normal length (150 mm) stems (p = 0.676). More uncemented stems subsided (Cemented stems: 1/122, 0.8%; Uncemented stems: 27/244, 11.1%; p < 0.001). Suboptimum cementation was noted in 16 (13%) hips; two fractured and one subsided (risk-ratio [RR]: 3.9; p = 0.035). A narrow ischial width and high ilio-ischial ratio were the only morphological parameters associated with risk of PPF and subsidence. Conclusion Hybrid AA-THA did not reduce PFF risk. Suboptimal cementation was associated with increased risk of subsidence or fracture. Current instruments do not accommodate the limited working window and steeper femoral angle during AA-THA.Keywords
All Related Versions
This publication has 45 references indexed in Scilit:
- Biomechanics of a cemented short stem: a comparative in vitro study regarding primary stability and maximum fracture loadArchives of orthopaedic and trauma surgery, 2021
- Quality of the femoral cement mantle in total hip arthroplasty using the direct anterior hip approachArthroplasty Today, 2020
- Is the Anterior Approach Safe? Early Complication Rate Associated With 5090 Consecutive Primary Total Hip Arthroplasty Procedures Performed Using the Anterior ApproachThe Journal of Arthroplasty, 2016
- Anterior and Anterolateral Approaches for THA Are Associated With Lower Dislocation Risk Without Higher Revision RiskClinical Orthopaedics and Related Research, 2015
- Anterior vs. Posterior Approach for Total Hip Arthroplasty, a Systematic Review and Meta-analysisThe Journal of Arthroplasty, 2015
- Periprosthetic Fracture Torque for Short Versus Standard Cemented Hip Stems: An Experimental In Vitro StudyThe Journal of Arthroplasty, 2014
- Does the Direct Anterior Approach in THA Offer Faster Rehabilitation and Comparable Safety to the Posterior Approach?Clinical Orthopaedics and Related Research, 2013
- A Short Tapered Stem Reduces Intraoperative Complications in Primary Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2012
- Does the anterior approach for total hip arthroplasty better restore stair climbing gait mechanics?Journal of Orthopaedic Research, 2011
- Dislocation After Total Hip Arthroplasty Using Hueter Anterior ApproachThe Journal of Arthroplasty, 2008