Automatic vs Manual Control Strategy for Window Blinds and Ceiling Lights: Consequences to Perceived Visual and Thermal Discomfort
Open Access
- 1 December 2019
- journal article
- Published by SolarLits in Journal of Daylighting
- Vol. 6 (2) , 112-123
Abstract
A case study to evaluate the occupants' satisfaction in relation to two different control strategies (fully automatic and manual) for blind and ceiling lights use in cell offices was carried on in Trondheim, Norway. A group of 11 participants with varying age, gender, and ethnicity, used two test cells of a laboratory as a workspace primarily carrying out office tasks at a personal computer for a total of 19 calendar days. The participants were asked to answer a computer-based questionnaire for reporting their perceived thermal and visual comfort. Concurrently, measurements of the indoor operative temperature, illuminance level, and operation of windows, blinds, and ceiling lights were registered. Results shows that the use of the automatic control strategy led to a higher visual discomfort, which in addition led to a higher thermal discomfort, despite this last not caused by a higher average operative temperature. Header of solarlits.comKeywords
This publication has 30 references indexed in Scilit:
- A review of open loop control strategies for shades, blinds and integrated lighting by use of real-time daylight prediction methodsBuilding and Environment, 2018
- Energy and comfort in contemporary open plan and traditional personal officesApplied Energy, 2017
- Occupant interactions with shading and lighting systems using different control interfaces: A pilot field studyBuilding and Environment, 2016
- Mitigating office performance uncertainty of occupant use of window blinds and lighting using robust designBuilding Simulation, 2015
- Building automation and perceived control: A field study on motorized exterior blinds in Dutch officesBuilding and Environment, 2014
- Manually-operated window shade patterns in office buildings: A critical reviewBuilding and Environment, 2013
- An experimental study on the environmental performance of the automated blind in summerBuilding and Environment, 2009
- Considerations for lighting in the built environment: Non-visual effects of lightEnergy and Buildings, 2006
- Occupant preferences and satisfaction with the luminous environment and control systems in daylit offices: a literature reviewEnergy and Buildings, 2006
- Window blind occlusion: a pilot studyBuilding and Environment, 1984