Retrospective Motion Correction in Multishot MRI using Generative Adversarial Network
Open Access
- 16 March 2020
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-11
Abstract
Multishot Magnetic Resonance Imaging (MRI) is a promising data acquisition technique that can produce a high-resolution image with relatively less data acquisition time than the standard spin echo. The downside of multishot MRI is that it is very sensitive to subject motion and even small levels of motion during the scan can produce artifacts in the final magnetic resonance (MR) image, which may result in a misdiagnosis. Numerous efforts have focused on addressing this issue; however, all of these proposals are limited in terms of how much motion they can correct and require excessive computational time. In this paper, we propose a novel generative adversarial network (GAN)-based conjugate gradient SENSE (CG-SENSE) reconstruction framework for motion correction in multishot MRI. First CG-SENSE reconstruction is employed to reconstruct an image from the motion-corrupted k-space data and then the GAN-based proposed framework is applied to correct the motion artifacts. The proposed method has been rigorously evaluated on synthetically corrupted data on varying degrees of motion, numbers of shots, and encoding trajectories. Our analyses (both quantitative as well as qualitative/visual analysis) establish that the proposed method is robust and reduces several-fold the computational time reported by the current state-of-the-art technique.Keywords
All Related Versions
This publication has 41 references indexed in Scilit:
- Prospective motion correction of high-resolution magnetic resonance imaging data in childrenNeuroImage, 2010
- A graphical generalized implementation of SENSE reconstruction using MatlabConcepts in Magnetic Resonance Part A, 2010
- POCS-enhanced correction of motion artifacts in parallel MRIMagnetic Resonance in Medicine, 2010
- Matrix description of general motion correction applied to multishot imagesMagnetic Resonance in Medicine, 2005
- Detection and elimination of motion artifacts by regeneration of k‐spaceMagnetic Resonance in Medicine, 2002
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- A class of fast Gaussian binomial filters for speech and image processingIEEE Transactions on Signal Processing, 1991
- Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imagingMagnetic Resonance in Medicine, 1990
- REAL-TIME NUCLEAR MAGNETIC RESONANCE CLINICAL IMAGING IN PAEDIATRICSThe Lancet, 1983