A novel fluorescent cardiac imaging system for preclinical intraoperative angiography
Open Access
- 25 February 2021
- journal article
- research article
- Published by Springer Nature in BMC Medical Imaging
- Vol. 21 (1) , 1-8
Abstract
Background: Intraoperative coronary angiography can tremendously reduce early coronary bypass graft failures. Fluorescent cardiac imaging provides an advanced method for intraoperative observation and real-time quantitation of blood flow with high resolution.Methods: We devised a system comprised of an LED light source, special filters, lenses and a detector for preclinical coronary artery angiography. The optical setup was implemented by using two achromatic doublet lenses, two positive meniscus lenses, a band-pass filter, a pinhole and a CCD sensor. The setup was optimized by Zemax software. Optical design was further challenged to obtain more parallel light beams, less diffusion and higher resolutions to levels as small as arterioles. Ex vivo rat hearts were prepared and coronary arteries were retrogradely perfused by indocyanine green (ICG). Video angiography was employed to assess blood flow and plot time-dependent fluorescence intensity curve (TIC). Quantitation of blood flow was performed by calculating either the gradient of TIC or area under curve. The correlation between blood flow and each calculated parameters was assessed and used to evaluate the quality of flow.Results: High-resolution images of flow in coronary arteries were obtained as precise as 62 µm vessel diameter, by our custom-made ICG angiography system. The gradient of TIC was 3.4–6.3 s−1, while the area under curve indicated 712–1282 s values which ultimately gained correlation coefficients of 0.9938 and 0.9951 with relative blood flow, respectively.Conclusion: The present ICG angiography system may facilitate evaluation of blood flow in animal studies of myocardial infarction and coronary artery grafts intraoperatively.Keywords
This publication has 28 references indexed in Scilit:
- Repopulation of decellularized mouse heart with human induced pluripotent stem cell-derived cardiovascular progenitor cellsNature Communications, 2013
- A Review of Indocyanine Green Fluorescent Imaging in SurgeryInternational Journal of Biomedical Imaging, 2012
- Intraoperative Grafts AssessmentSeminars in Thoracic and Cardiovascular Surgery, 2009
- Assessment of Graft Patency During Coronary Artery Bypass Graft SurgeryJACC: Cardiovascular Imaging, 2009
- Intraoperative coronary graft assessmentCurrent Opinion in Cardiology, 2008
- Fluorescent Cardiac ImagingCirculation, 2007
- Preliminary experience with a novel fluorescence lymphography using indocyanine green in patients with secondary lymphedemaJournal of Vascular Surgery, 2007
- Improving the Quality of Coronary Bypass Surgery With Intraoperative AngiographyJACC, 2005
- A comparison of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patencyThe Journal of Thoracic and Cardiovascular Surgery, 2005
- Novadaq SPYChest, 2004