Locking Compression Plate Fixation of Vancouver Type-B1 Periprosthetic Femoral Fractures
Authors:
- M.A. ButtaroMBM.A. Buttaro
- G. FarfalliGFG. Farfalli
- M. Paredes NúñezMNM. Paredes Núñez
- F. CombaFCF. Comba
- F. PiccalugaFPF. Piccaluga
- 1 September 2007
- journal article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 89 (9) , 1964-1969
Abstract
Multiple points of unicortical fixation. Such unicortical fixation may lower the risk of damage to the cement mantle or a stable femoral stem during the treatment of a periprosthetic femoral fracture. The purpose of this study was to analyze clinically and radiographically a group of patients with a Vancouver type-B1 periprosthetic femoral fracture treated with open reduction and internal fixation with use of a locking compression plate....Keywords
This publication has 12 references indexed in Scilit:
- Low Complication Rate of LISS for Femur Fractures Adjacent to Stable Hip or Knee ArthroplastyClinical Orthopaedics and Related Research, 2006
- Dynamic compression plate fixation for post-operative fractures around the tip of a hip prosthesisInjury, 2005
- Periprosthetic Fractures Evaluation and TreatmentClinical Orthopaedics and Related Research, 2004
- Guidelines for the clinical application of the LCPInjury, 2003
- Dall-Miles plates for periprosthetic femoral fracturesInjury, 2003
- Dall-Miles plating for periprosthetic B1 fractures of the femurThe Journal of Arthroplasty, 2000
- CLASSIFICATION OF THE HIPOrthopedic Clinics of North America, 1999
- Distal Femoral Fixation: A Biomechanical Comparison of the Standard Condylar Buttress Plate, a Locked Buttress Plate, and the 95-Degree Blade PlateJournal of Orthopaedic Trauma, 1997
- Periprosthetic Fractures of the FemurClinical Orthopaedics and Related Research, 1996
- Treatment of fractures about hip prostheses with compression platingThe Journal of Arthroplasty, 1992