Successful one-lung ventilation using the VivaSight-EB bronchial blocker tube for an emergency lung injury. A simulation pilot data
Authors:
Open Access
- 12 December 2019
- journal article
- Published by VM Media Group sp. z o.o in Disaster and Emergency Medicine Journal
- Vol. 4 (4) , 131-136
Abstract
INTRODUCTION: The ability to perform endotracheal intubation is one of the basic skills that paramedics should demonstrate. However, in some cases where lung or bronchial injuries have occurred, it may be necessary to separate the lung by attaching a bronchial blocker and ventilating single lung. The aim of the study was to evaluate the effectiveness of bronchial protection with VivaSight-EB bronchial blocker tube and one-lung ventilation by paramedics in conditions of simulated lung injury. MATERIAL AND METHODS: The study was a prospective randomized cross-over simulation trial in which 27 paramedics took part. In the study, paramedics performed endotracheal intubation with ETView SL and then introduced a VivaSight-EB bronchial blocker and one-lung ventilation. The bronchial protection procedure took place in two scenarios: (A) normal airway; (B) difficult airway. VivaSight-EB bronchial blocker introduction time (T1) and one-lung ventilation time (T2) and the efficacy of the procedure were analysed. RESULTS: The efficacy of endotracheal intubation with ETView SL tube was 100% during both Scenario A and Scenario B. The efficacy of endotracheal intubation with ETView SL tube was 100%. The effectiveness of the first attempt to protect the bronchi with a bronchial blocker was 26% for both scenarios and the total effectiveness of bronchial protection was 100% in both cases. Time T1 for endotracheal intubation was 18sec for Scenario A (IQR; 16.5–25) and 20 sec for Scenario B (IQR; 17–25). The time to perform one-lung ventilation (Time T2) in scenarios A and B was 43 sec (IQR; 38–62.5) vs. 43.5 sec (38–65). CONCLUSIONS: The simulation study confirmed the research hypothesis that the paramedics were able to perform one-lung ventilation using the ETView-Blocker® bronchial blocker tube after a short training. INTRODUCTION: The ability to perform endotracheal intubation is one of the basic skills that paramedics should demonstrate. However, in some cases where lung or bronchial injuries have occurred, it may be necessary to separate the lung by attaching a bronchial blocker and ventilating single lung. The aim of the study was to evaluate the effectiveness of bronchial protection with VivaSight-EB bronchial blocker tube and one-lung ventilation by paramedics in conditions of simulated lung injury. MATERIAL AND METHODS: The study was a prospective randomized cross-over simulation trial in which 27 paramedics took part. In the study, paramedics performed endotracheal intubation with ETView SL and then introduced a VivaSight-EB bronchial blocker and one-lung ventilation. The bronchial protection procedure took place in two scenarios: (A) normal airway; (B) difficult airway. VivaSight-EB bronchial blocker introduction time (T1) and one-lung ventilation time (T2) and the efficacy of the procedure were analysed. RESULTS: The efficacy of endotracheal intubation with ETView SL tube was 100% during both Scenario A and Scenario B. The efficacy of endotracheal intubation with ETView SL tube was 100%. The effectiveness of the first attempt to protect the bronchi with a bronchial blocker was 26% for both scenarios and the total effectiveness of bronchial protection was 100% in both cases. Time T1 for endotracheal intubation was 18sec for Scenario A (IQR; 16.5–25) and 20 sec for Scenario B (IQR; 17–25). The time to perform one-lung ventilation (Time T2) in scenarios A and B was 43 sec (IQR; 38–62.5) vs. 43.5 sec (38–65). CONCLUSIONS: The simulation study confirmed the research hypothesis that the paramedics were able to perform one-lung ventilation using the ETView-Blocker® bronchial blocker tube after a short training.Keywords
This publication has 25 references indexed in Scilit:
- Airway Management in the Thoracic Anesthesia with the Double-Lumen TubeAINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie, 2018
- Procedural training and assessment of competency utilizing simulationSeminars in Perinatology, 2016
- The role of prehospital advanced airway management on outcomes for out-of-hospital cardiac arrest patients: a meta-analysisThe American Journal of Emergency Medicine, 2016
- Comparison of ETView SL, Airtraq, and Macintosh laryngoscopes for face-to-face tracheal intubation: a randomized crossover manikin trialThe American Journal of Emergency Medicine, 2016
- The uses of laryngeal mask airway ProSeal™ and endobronchial blocker for one lung anesthesiaJournal of Anesthesia, 2015
- Advanced airway management is necessary in prehospital trauma patientsBritish Journal of Anaesthesia, 2014
- Right Ventricular Function During One-Lung Ventilation: Effects of Pressure-Controlled and Volume-Controlled VentilationJournal of Cardiothoracic and Vascular Anesthesia, 2014
- Trauma Airway Management: Transition from Anesthesia to Emergency MedicineThe Journal of Emergency Medicine, 2013
- Notfallnarkose, Atemwegsmanagement und Beatmung beim PolytraumaDer Anaesthesist, 2011
- Features and uses of high-fidelity medical simulations that lead to effective learning: a BEME systematic reviewMedical Teacher, 2005