Optimal location and geometry of sensors and actuators for active vibration control of smart composite beams
Authors:
- 1 June 2020
- journal article
- research article
- Published by Taylor & Francis in Australian Journal of Mechanical Engineering
- Vol. 20 (4) , 981-999
Abstract
This work investigates the problem of optimal placement and geometry of piezoelectric sensors and actuators (S/A) to improve active vibration control performance of smart laminated beam. Theoretical formulation is based on efficient layer-wise finite element model along with an optimal control theory. Control theory is implemented in state space format considering a reduced order model. A laminated beam with collocated piezoelectric S/A placed at the top and bottom surfaces has been considered. A series of simulation based on Taguchi design of experiment has been carried out to determine the optimal placement and geometry of the S/A to achieve best control performance that is maximum modal active damping ratio /minimum settling time with minimum actuator voltage. A multi-criteria optimisation has been performed using Proximity Indexed Value (PIV) integrated with entropy methods. Further, the analysis of mean (ANOM) and analysis of variance (ANOVA) are performed to identify the most significant input parameter based on their percentage contribution. For the smart cantilever beam considered in the analysis, the location of the S/A is the most significant having maximum percentage contribution (35.69%) followed by its length (33.04%) and thickness (24.55%).
Keywords
Funding Information
- Anusandhan National Research Foundation (YSS/2017/002070)
This publication has 67 references indexed in Scilit:
- Selection of optimal machining parameters using integrated MCDM approachesInternational Journal of Advanced Operations Management, 2018
- Active control of geometrically non-linear transient response of sandwich beams with a flexible core using piezoelectric patchesComposite Structures, 2013
- Application of a novel measure of EEG non-stationarity as ‘Shannon- entropy of the peak frequency shifting’ for detecting residual abnormalities in concussed individualsClinical Neurophysiology, 2011
- Optimal Location of Actuators and Sensors in Active Vibration ControlJournal of Intelligent Material Systems and Structures, 2005
- Active Structural Vibration Control: A ReviewThe Shock and Vibration Digest, 2003
- Review of State of Art of Smart Structures and Integrated SystemsAIAA Journal, 2002
- Advances in piezoelectric finite element modeling of adaptive structural elements: a surveyComputers & Structures, 2000
- Piezoelectric actuator design for vibration suppression - Placement and sizingJournal of Guidance, Control, and Dynamics, 1993
- Performance of an active control system with piezoelectric actuatorsJournal of Sound and Vibration, 1988
- Distributed piezoelectric-polymer active vibration control of a cantilever beamJournal of Guidance, Control, and Dynamics, 1985