Compression Real‐time Elastography for Evaluation of Salivary Gland Lesions
Authors:
- 12 April 2016
- journal article
- research article
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 35 (5) , 999-1007
Abstract
Objectives: To evaluate the performance of compression real‐time elastography for differentiation between benign and malignant salivary gland lesions.Methods: A systematic literature database search was conducted. Pooled sensitivity, specificity, positive likelihood ratio (LR+), and negative likelihood ratio (LR−) values for real‐time elastography were analyzed. Summary receiver operating characteristic (ROC) curves were also constructed. Heterogeneity was evaluated by χ2 and I2 tests. I2 > 50% or P < .05 indicated heterogeneity, and then a random‐effects model was applied. A Deek funnel plot was used to assess publication bias. Fagan plot analysis was performed to evaluate the clinical utility of real‐time elastography. When heterogeneity was found, subgroup analyses were used to explore the sources of heterogeneity. A sensitivity analysis was conducted by omitting 1 study at a time and examining the influence of each individual study on the overall results.Results: Nine articles with 581 lesions were included. The pooled sensitivity and specificity of real‐time elastography for differentiation between benign and malignant lesions were 76% (95% confidence interval [CI], 65%–85%; 95% prediction interval [PI], 29%–95%) and 73% (95% CI, 62%–81%; 95% PI, 24%–96%), respectively. The LR+ and LR− were 2.81 (95% CI, 1.79–4.39; 95% PI, 0.65–12.16) and 0.33 (95% CI, 0.20–0.55; 95% PI, 0.07–1.69). The area under the ROC curve was 0.81 (95% CI, 0.77–0.84). No publication bias was detected, according to the Deek funnel plot (P = .51). The Fagan plot showed that when pretest probabilities were 25%, 50%, and 75%, positive posttest probabilities were 48%, 74%, and 89%, and negative probabilities were 10%, 25%, and 50%.Conclusions: Real‐time elastography is a novel supplementary adjunct to conventional sonography for evaluation of salivary gland lesions. However, its overall accuracy is less promising, and biopsy may still be necessary in routine clinical practice.Keywords
This publication has 24 references indexed in Scilit:
- Early results of real-time qualitative sonoelastography in the evaluation of parotid gland masses: A study with histopathological correlationActa Radiologica, 2013
- Is sonoelastography a helpful method for evaluation of parotid tumors?European Archives of Oto-Rhino-Laryngology, 2012
- Quantitative analysis of elastography images in the detection of breast cancerEuropean Journal of Radiology, 2012
- Shear wave elastography of thyroid nodules in routine clinical practice: preliminary observations and utility for detecting malignancyEuropean Radiology, 2012
- Real-Time Sonoelastography of Major Salivary Gland TumorsAmerican Journal of Roentgenology, 2011
- Real-time elastography for the differentiation of benign and malignant breast lesions: a meta-analysisBreast Cancer Research and Treatment, 2011
- Imaging the major salivary glandsBritish Journal of Oral and Maxillofacial Surgery, 2011
- Evaluation of real-time qualitative sonoelastography of focal lesions in the parotid and submandibular glands: applications and limitationsEuropean Radiology, 2010
- Multicenter Study of Ultrasound Real-Time Tissue Elastography in 779 Cases for the Assessment of Breast Lesions: Improved Diagnostic Performance by Combining the BI-RADS®-US Classification System with SonoelastographyUltraschall in der Medizin - European Journal of Ultrasound, 2010
- Imaging of salivary gland tumoursEuropean Journal of Radiology, 2008