On the separation of enantiomers by drift tube ion mobility spectrometry
- 18 July 2022
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 14 (31) , 3011-3020
Abstract
Racemic mixtures of twelve common α-amino acids and three chiral drugs were tested for the separation of their enantiomers by drift tube ion mobility spectrometry (IMS)-quadrupole mass spectrometry (QMS) by introducing chiral selectors into the buffer gas of the IMS instrument. (R)-α-(Trifluoromethyl)benzyl alcohol, (L)-ethyl lactate, methyl (S)-2-chloropropionate, and the R and S enantiomers of 2-butanol and 1-phenyl ethanol were evaluated as chiral selectors. Experimental conditions were varied during the tests, including buffer gas temperature, concentration and type of chiral selectors, analyte concentration, electrospray (ESI) voltage, ESI solvent pH, and buffer gas flow rate. The individual enantiomers yielded the same drift times and the racemic mixtures could not be separated. Energy calculations of the chiral selector–ion interactions showed that these separations are unlikely using 2-butanol as a chiral selector but they might be theoretically feasible depending on the chiral selector nature and the type of enantiomers. Several plausible explanations for not achieving separations were analyzed. Recommendations for potential enantiomer separations by IMS are proposed.Keywords
All Related Versions
Funding Information
- Fulbright Colombia
- Washington State University
This publication has 28 references indexed in Scilit:
- ωB97X-V: A 10-parameter, range-separated hybrid, generalized gradient approximation density functional with nonlocal correlation, designed by a survival-of-the-fittest strategyPhysical Chemistry Chemical Physics, 2013
- Physical aspects of the emergence of living cell precursors: the ion and chiral asymmetries as two fundamental asymmetry typesMoscow University Physics Bulletin, 2008
- Gas-Phase Chiral Separations by Ion Mobility SpectrometryAnalytical Chemistry, 2006
- Balanced basis sets of split valence, triple zeta valence and quadruple zeta valence quality for H to Rn: Design and assessment of accuracyPhysical Chemistry Chemical Physics, 2005
- Peer Reviewed: Chiral analysis by MSAnalytical Chemistry, 2003
- Electrospray Ionization High-Resolution Ion Mobility Spectrometry−Mass SpectrometryAnalytical Chemistry, 1998
- Conversion of L- to D-Amino Acids: A Posttranslational ReactionScience, 1994
- Considerations of chiral recognition relevant to the liquid chromatography separation of enantiomersChemical Reviews, 1989
- Kinetics of racemization of amino acids as a function of pHJournal of the American Chemical Society, 1972
- Thalidomide Disaster Considered as an Experiment in Mammalian TeratologyBMJ, 1962