Characterization of exposure to byproducts from firing lead-free frangible ammunition in an enclosed, ventilated firing range
- 26 February 2017
- journal article
- research article
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 14 (6) , 461-472
Abstract
U.S. Air Force small arms firing ranges began using copper-based, lead-free frangible ammunition in the early 2000s due to environmental and health concerns related to the use of lead-based ammunition. Exposure assessments at these firing ranges have routinely detected chemicals and metals in amounts much lower than their mass-based occupational exposure limits, yet, instructors report work-related health concerns including respiratory distress, nausea, and headache. The objective of this study at one firing range was to characterize the aerosol emissions produced by weapons during firing events and evaluate the ventilation system's effectiveness in controlling instructor exposure to these emissions. The ventilation system was assessed by measuring the range static air pressure differential and the air velocity at the firing line. Air flow patterns were near the firing line. Instructor exposure was sampled using a filter-based air sampling method for metals and a wearable, real-time ultrafine particle counter. Area air sampling was simultaneously performed to characterize the particle size distribution, morphology, and composition. In the instructor's breathing zone, the airborne mass concentration of copper was low (range = 3 to 16 µg/m3), yet the ultrafine (nanoscale) particle number concentration increased substantially during each firing event. Ultrafine particles contained some copper and were complex in morphology and composition. The ventilation assessment found that the average velocity across all shooting lanes was acceptable compared to the recommended guideline (20% of the ideal 0.38 m/s (75 ft/min). However, uniform, downrange airflow pattern requirements were not met. These results suggest that the mass-based occupational exposure limits, as applied to this environment, may not be protective enough to eliminate health complaints reported by instructors whose full-time job involves training personnel on weapons that fire lead-free frangible ammunition. Using an ultrafine particle counter appears to be an alternative method of assessing ventilation effectiveness in removing ultrafine particulate produced during firing events.Keywords
This publication has 23 references indexed in Scilit:
- Emission Factors for Gases and Particle-Bound Substances Produced by Firing Lead-Free Small-Caliber AmmunitionJournal of Occupational and Environmental Hygiene, 2014
- Particulate Matter Air Pollution and Cardiovascular DiseaseCirculation, 2010
- Concordance BetweenInVitroandInVivoDosimetry in the Proinflammatory Effects of Low-Toxicity, Low-Solubility Particles: The Key Role of the Proximal Alveolar RegionInhalation Toxicology, 2008
- Proinflammogenic Effects of Low-Toxicity and Metal Nanoparticles In Vivo and In Vitro: Highlighting the Role of Particle Surface Area and Surface ReactivityInhalation Toxicology, 2007
- Ultrafine particulate pollutants induce oxidative stress and mitochondrial damage.Environmental Health Perspectives, 2003
- The Pulmonary Toxicology of Ultrafine ParticlesJournal of Aerosol Medicine, 2002
- The surface area rather than the surface coating determines the acute inflammatory response after instillation of fine and ultrafine TiO2 in the ratInternational Journal of Hygiene and Environmental Health, 2002
- Pulmonary effects of inhaled ultrafine particlesInternational Archives of Occupational and Environmental Health, 2000
- Ultrafine (nanometre) particle mediated lung injuryJournal of Aerosol Science, 1998
- Simulation of Aerosol Size Distribution Evolution in Systems with Simultaneous Nucleation, Condensation, and CoagulationAerosol Science and Technology, 1985