In vivo real‐time diagnosis of endoscopic ultrasound‐guided needle‐based confocal laser endomicroscopy in gastric subepithelial lesions
- 13 September 2019
- journal article
- research article
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 35 (3) , 446-452
Abstract
Background and aim The effect of real‐time analysis of needle‐based confocal laser endomicroscopy (nCLE) for gastric subepithelial lesions (SELs) on the diagnostic value is unclear. The study aimed to investigate the diagnostic efficacy of real‐time nCLE for gastric SELs and to assess the technical aspects and safety of real‐time nCLE. Methods Consecutive patients with gastric SELs ≥ 1 cm were prospectively investigated by endoscopic ultrasound (EUS), followed by nCLE. During EUS‐nCLE, real‐time nCLE diagnosis was made by an expert endoscopist. The procedure‐relative adverse events were assessed and recorded. One‐month wash‐out period later, nCLE videos were reviewed off‐line by the same endoscopist. The nCLE diagnoses were compared with corresponding pathological results. Additionally, image quality and interobserver agreements for the criteria were evaluated by three experienced endomicroscopists. Results Except for one failing to be punctured, 60 patients completed EUS‐nCLE procedures successfully. Real‐time nCLE had high diagnostic accuracies of ≥ 88.3% for gastric SELs. There were no significant differences between real‐time and off‐line nCLE diagnoses for gastric SELs (P > 0.05). The overall accuracy of real‐time nCLE for diagnosis of gastric SELs was 86.7%. There were no procedure‐relative adverse events occurred. In addition, the mean image quality score was 3.6 (1 = poor and 5 = excellent). The interobserver agreement was “almost perfect” for ectopic pancreas and “substantial” for gastrointestinal stromal tumor, leiomyoma and carcinoma. Conclusions EUS‐nCLE could provide in vivo real‐time diagnostic imaging with a high diagnostic accuracy. Meanwhile, real‐time nCLE was feasible and had a satisfactory safety profile.Keywords
Funding Information
- Key Technology Research and Development Program of Shandong Province (2018CXGC1209)
- Key Technology Research and Development Program of Shandong Province (2017YFC0110003, 2017YFC0109700)
- National Natural Science Foundation of China (81670489)
This publication has 21 references indexed in Scilit:
- Comparison of FNA and fine-needle biopsy for EUS-guided sampling of suspected GI stromal tumorsGastrointestinal Endoscopy, 2017
- Endoscopic ultrasound without tissue acquisition has poor accuracy for diagnosing gastric subepithelial tumorsMedicine, 2016
- Diagnostic utility of EUS-guided FNA in patients with gastric submucosal tumorsGastrointestinal Endoscopy, 2010
- Accuracy of EUS in the evaluation of small gastric subepithelial lesionsGastrointestinal Endoscopy, 2010
- Endoscopic ultrasound-guided fine-needle aspiration and trucut biopsy in the diagnosis of gastric stromal tumors: a randomized crossover studyEndoscopy, 2010
- Prospective comparison of endoscopic ultrasound-guided fine-needle aspiration and surgical histology in upper gastrointestinal submucosal tumorsEndoscopy, 2010
- Preoperative diagnosis of gastrointestinal stromal tumor by endoscopic ultrasound-guided fine needle aspirationWorld Journal of Gastroenterology, 2007
- American Gastroenterological Association Institute Technical Review on the Management of Gastric Subepithelial MassesGastroenterology, 2006
- Comparison of EUS-Guided 19-Gauge Trucut Needle Biopsy With EUS-Guided Fine-Needle AspirationEndoscopy, 2004
- Endoscopic ultrasound guided fine needle aspiration biopsy: a large single centre experienceGut, 1999