Indoor radon in Tunisian spas
Open Access
- 1 July 2012
- journal article
- research article
- Published by EDP Sciences in Radioprotection
- Vol. 47 (3) , 361-373
Abstract
Indoor radon concentrations were measured in four well-known spas of Tunisia using nuclear track detectors. The radon concentrations in these spas were found to be in the range of 19 - 870 Bq.m-3. The equilibrium factor F between radon and its progeny was found to vary in the range of 0.2 - 0.5, depending upon the ventilation rates within the buildings of the spas. Using the exposure-dose conversion factor, the effective doses to patients and workers were estimated and the dose was found to vary in the range 3.7 × 10-3 - 12.5 × 10-3 mSv.y-1 and 0.45 - 1.5 mSv.y-1 for patients and workers, respectively. These values are well inside the limit recommended for the annual dose limit of 20 mSv.y-1 for an occupational worker. The radium content in the groundwater of all four spas was measured and the results showed no correlation between the 226Ra concentration in water and radon concentration in indoor air of the investigated spas.Keywords
This publication has 25 references indexed in Scilit:
- Modelling of radon concentration peaks in thermal spas: Application to Polichnitos and Eftalou spas (Lesvos Island—Greece)Science of The Total Environment, 2008
- Etude intégrée des données de surface et de subsurface pour la prospection des bassins hydrogéothermiques: cas du bassin de Maknassy (Tunisie centrale) /Integrated study of surface and subsurface data for prospecting hydrogeothermal basins: case of the Maknassy basin (central Tunisia)Hydrological Sciences Journal, 2007
- Modelling radon progeny concentration variations in thermal spasScience of The Total Environment, 2007
- Estimation of the radiological risk related to the presence of radon 222 in a hydrotherapy centre in TunisiaJournal of Radiological Protection, 2006
- Relevance of air conditioning for 222Radon concentration in shops of the Savona Province, ItalyScience of The Total Environment, 2006
- Indoor radon levels in selected hot spring hotels in Guangdong, ChinaScience of The Total Environment, 2005
- Quantification of water exchange between a hill reservoir and groundwater using hydrological and isotopic modelling (El Gouazine, Tunisia)Comptes Rendus. Géoscience, 2004
- Radon exposure in the thermal spas of Lesvos Island--GreeceRadiation Protection Dosimetry, 2004
- Le radon dans les stations thermales : une source d'exposition aux rayonnements ionisantsRadioprotection, 2003
- Occupational exposure to radon in treatment facilities of the radon-spa Badgastein, AustriaEnvironment International, 1996