Dose-Volume Predictors of Esophagitis After Thoracic Stereotactic Body Radiation Therapy
Authors:
- Eileen M. HarderEHEileen M. Harder
- Zhe (Jay) ChenZCZhe (Jay) Chen
- Henry S. ParkHenry S. Park
- Brandon R. ManciniBMBrandon R. Mancini
- Roy H. DeckerRDRoy H. Decker
- 1 October 2017
- journal article
- clinical trial
- Published by Wolters Kluwer Health in American Journal of Clinical Oncology
- Vol. 40 (5) , 477-482
Abstract
Esophageal toxicity has become a major concern as stereotactic hypofractionated radiation therapy is increasingly utilized for central pulmonary tumors. Our purpose was to define esophageal dosimetric parameters that predict potentially dose-limiting toxicities. In total, 157 patients with a planning target volume ≤5 cm from the esophagus were selected from an institutional database. Toxicity was scored with the CTCAE v4.0. Esophageal Dmax and Dv (dose D in Gy covering volume v in mL) in 0.5 mL increments were collected. Corresponding biologically effective dose (BED) was calculated for α/β=10,3 (BED10, BED3). Normal tissue complication probability was computed with conventionally fractionated radiotherapy parameters and equivalent dose in 2 Gy per fraction (EQD2). Dosimetric predictors were identified with multivariate logistic regression with a manual forward stepwise selection technique. The grade≥2 esophagitis rate was 5.7%. BED10 to 1.5 mL was the best predictor of esophagitis. BED10 to 0.5, 1.0, 2.0, 3.0, and 3.5 mL were also predictive but less strong. Results were similar when BED3 and physical dose were examined. Tumor-esophageal distance correlated with esophagitis (10.5% risk of≥grade 2 events with distance≤3.9 cm vs. 1.3% when>3.9 cm, P=0.016). BED10 to 1.5 mL correlated well with EQD2 normal tissue complication probability estimates. BED to 1.5 mL was the strongest predictor of grade≥2 esophagitis (independent of α/β ratio) with a 10.6% toxicity risk when BED10>21.1 Gy (14.3 Gy in 3 fractions, 16.0 Gy in 5). The overall rate of severe toxicity is low, suggesting that higher doses may be tolerable.Keywords
This publication has 31 references indexed in Scilit:
- Esophageal Toxicity From High-Dose, Single-Fraction Paraspinal Stereotactic RadiosurgeryInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Stereotactic Body Radiotherapy (SBRT) for Operable Stage I Non–Small-Cell Lung Cancer: Can SBRT Be Comparable to Surgery?International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Consideration of Dose Limits for Organs at Risk of Thoracic Radiotherapy: Atlas for Lung, Proximal Bronchial Tree, Esophagus, Spinal Cord, Ribs, and Brachial PlexusInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Stereotactic body radiation therapy: The report of AAPM Task Group 101Medical Physics, 2010
- Radiation Dose-Volume Effects in the EsophagusInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Low rate of thoracic toxicity in palliative paraspinal single-fraction stereotactic body radiation therapyRadiotherapy and Oncology, 2009
- Implications of Respiratory Motion as Measured by Four-Dimensional Computed Tomography for Radiation Treatment Planning of Esophageal CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- An Overview of Hypofractionation and Introduction to This Issue of Seminars in Radiation OncologySeminars in Radiation Oncology, 2008
- Results of a Phase I Dose-Escalation Study Using Single-Fraction Stereotactic Radiotherapy for Lung TumorsJournal of Thoracic Oncology, 2006
- Accreditation and quality assurance for Radiation Therapy Oncology Group: Multicenter clinical trials using Stereotactic Body Radiation Therapy in lung cancerActa Oncologica, 2006