Comparative Analysis of Indoor Environmental Quality of Architectural Campus Buildings’ Lecture Halls and its’ Perception by Building Users, in Karachi, Pakistan
Open Access
- 8 April 2020
- journal article
- research article
- Published by MDPI AG in Sustainability
- Vol. 12 (7) , 2995
Abstract
Poor Indoor Environmental Quality (IEQ) adversely affects the performance and health of building users. Building users are an important source of information regarding IEQ and its influence on users’ wellbeing and productivity. This paper discusses the analysis and evaluation of IEQ in lecture halls of two public Architectural Campus Buildings (ACB) in Karachi, Pakistan. The method of this research is divided into three parts: (i) An analysis of local climate conditions, (ii) An on-site survey of two existing ACBs to analyze indoor environmental conditions. and (iii) The analysis of users’ satisfaction using a questionnaire survey. The research results showed that users are dissatisfied with existing hot and humid indoor environment conditions caused by interactions of local outdoor climate conditions, the building’s architecture, and inadequate ventilation within the building. The findings revealed that Karachi has 41.3% comfort hours with the warm sub-humid season to be the most comfortable season having 80.56% comfort hours. IEQ analysis unveiled that airflow in ACB1 is low, whereas, high airflow is observed in ACB2. The findings of this research unveiled that cross-ventilation by the adapted placement of openings, improved external shading devices, and provision of increased vegetation are required in both ACBs to achieve a more comfortable IEQ.Keywords
Funding Information
- Higher Education Commision, Pakistan (HRDI-UESTP scholarship program Batch- III with the ref. no. 50022580)
This publication has 39 references indexed in Scilit:
- Thermal comfort and energy consumption in a UK educational buildingBuilding and Environment, 2013
- Green occupants for green buildings: The missing link?Building and Environment, 2012
- Energy performance and indoor environmental quality in Hellenic schoolsEnergy and Buildings, 2011
- Winter indoor air quality, thermal comfort and acoustic performance of newly built secondary schools in EnglandBuilding and Environment, 2009
- Adaptive analysis of thermal comfort in university classrooms: Correlation between experimental data and mathematical modelsBuilding and Environment, 2009
- World Map of the Köppen-Geiger climate classification updatedMeteorologische Zeitschrift, 2006
- Listening to the occupants: a Web-based indoor environmental quality surveyIndoor Air, 2004
- Adaptive thermal comfort standards in the hot–humid tropicsEnergy and Buildings, 2004
- Climatic variations in comfortable temperatures: the Pakistan projectsEnergy and Buildings, 1999
- Pioneering new indoor temperature standards: the Pakistan projectEnergy and Buildings, 1996