Anin vitroandin vivocharacterization of fineWE43Bmagnesium wire with varied thermomechanical processing conditions
Authors:
- 9 October 2017
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 106 (5) , 1987-1997
Abstract
Absorbable implants made of magnesium alloys may revolutionize surgical intervention, and fine magnesium wire will be critical to many applications. Functionally, the wires must have sufficient mechanical properties to withstand implantation and in‐service loading, have excellent tissue tolerance, and exhibit an appropriate degradation rate for the application. Alloy chemistry and thermomechanical processing conditions will significantly impact the material's functional performance, but the exact translation of these parameters to implant performance is unclear. With this in mind, fine (127 µm) WE43B magnesium alloy wires in five thermomechanical process (TMP) conditions (90% cold work [CW], and 250, 375, 400, and 450°C heat treatments) were investigated for their effect on mechanical and corrosion behavior. The TMP conditions gave clear metallurgical differences: transverse grain dimensions ranged from 200 nm (CW) to 3 µm (450°C), UTS varied from 324 MPa (450°C) to 608 MPa (250°C), and surgical knotting showed some were suitable (CW, 400°C, 450°C) while others were not (250°C, 350°C).In vitroandin vivocorrosion testing yielded interesting and in some cases conflicting results. After 1 month immersion in cell culture medium, wire corrosion was extensive, and TMP conditions altered the macrocorrosion morphology but not the rate or total release of magnesium ions. After 1 month subdermal implantation in mice, all wires were well tolerated and showed very little corrosion (per µCT and histology), but differences in localized corrosion were detected between conditions. This study indicates that WE43B wires treated at 450°C may be most suitable for surgical knotting procedures. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1987–1997, 2018.Keywords
Funding Information
- NSF Engineering Research Center (ERC) for Revolutionizing Metallic Biomaterials (NSF EEC 0812348)
This publication has 18 references indexed in Scilit:
- Effects of magnesium degradation products on mesenchymal stem cell fate and osteoblastogenesisGene, 2016
- Initial observations on using magnesium metal in peripheral nerve repairJournal of Biomaterials Applications, 2014
- Biodegradable metalsMaterials Science and Engineering: R: Reports, 2014
- Influence of fine-grain and solid-solution strengthening on mechanical properties and in vitro degradation of WE43 alloyBiomedical Materials, 2014
- Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot studyBioMedical Engineering OnLine, 2013
- Biodegradable magnesium implants for orthopedic applicationsJournal of Materials Science, 2012
- Corrosion fatigue behaviors of two biomedical Mg alloys – AZ91D and WE43 – In simulated body fluidActa Biomaterialia, 2010
- Control of biodegradation of biocompatable magnesium alloysCorrosion Science, 2007
- In vivo corrosion of four magnesium alloys and the associated bone responseBiomaterials, 2005
- Drug‐Eluting Bioabsorbable Magnesium StentJournal of Interventional Cardiology, 2004