Abstract
The paper presents a numerical assessment of various room heating methods using assembled room models. It compares the efficiency of floor heating, ceiling heating, and plane radiator heating in a selected room of a family house under winter conditions in the Central European climate zone. COMSOL Multiphysics software was used for computer simulations. The output data were subsequently processed and analyzed using MATLAB software. Results indicate that floor and ceiling heating systems achieve higher and more rapid temperature increases compared to plane radiators. The distribution of air temperature within the room was also analyzed, revealing that floor heating provides the most uniform temperature distribution. These findings contribute to the development of effective heating strategies for residential buildings in similar climatic conditions. Furthermore, appropriate processing of output data obtained from computer simulations using artificial intelligence tools contributes to increasing the accuracy and efficiency of numerical analysis methods.

This publication has 27 references indexed in Scilit: