Triple Langmuir probe measurements in the Phaedrus-T tokamak
Authors:
- 1 October 1990
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 61 (10) , 2870-2872
Abstract
Triple Langmuir probe data have been obtained in the initial phase of Phaedrus‐T operation. The data were obtained during ohmic discharges of roughly 60 kA, 〈n〉=5×1018 m−3, Te(0)=0.5 keV, BT=0.7 T, q(a)=4 and 80 ms duration. Measurements of Te, φF, and n were made in a radial scan in the scrape‐off layer of the plasma. The toroidal and poloidal positions were fixed throughout the scan. The spectra of Te, φF, and n fluctuations up to 100 kHz were also measured. One of the interesting features of these data is that m=2 oscillations detected by Mirnov coils were very pronounced in the φF and Te fluctuation spectra, but are not as evident in the n fluctuations. These data are presented and the techniques employed to get these data are discussed. Future plans to extend the maximum frequency resolution of the fluctuation measurements up to and beyond the frequency range of the ICRF power (13–18 MHz) that will be injected into Phaedrus‐T are also discussed.Keywords
This publication has 4 references indexed in Scilit:
- Coherent mode activity in the edge of TOSCA TokamakPlasma Physics and Controlled Fusion, 1988
- DENSEPACK: An array of Langmuir probes in the limiter shadow plasma of the Alcator C tokamak fusion experimentReview of Scientific Instruments, 1986
- Particle and heat flux measurements in PDX edge plasmasJournal of Nuclear Materials, 1984
- Effect of bias on trapping probes and bolometers for Tokamak edge diagnosisJournal of Physics D: Applied Physics, 1982