Sonographically guided hydrostatic reduction of intussusception in children
Authors:
- 26 June 2002
- journal article
- research article
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 30 (6) , 343-348
Abstract
Purpose.: The aim of this study was to assess the efficacy of sonographically guided hydrostatic enema in therapeutic reduction of intussusception in children and to determine whether certain factors may predict the outcome of this technique.Methods.: We retrospectively reviewed the medical records and sonographic examinations of 83 consecutive children sonographically diagnosed with 101 cases of intussusception over a 40‐month period. In 99 cases, sonographically guided hydrostatic reduction was attempted. The presence of free peritoneal fluid, the presence of fluid inside the intussusception, and the initial location of the intussusception, as confirmed by sonography, along with the level of experience of the radiologist who performed the reduction were statistically analyzed to determine their effect on outcome. A p value less than 0.05 was considered significant.Results.: In 88 (89%) of the 99 cases, hydrostatic reduction was successful. No complications during or after hydrostatic enema were noted. The success rate was significantly lower among patients whose intussusception was located in the left side of the abdomen (p < 0.01) or contained entrapped fluid (p < 0.02) or those in whom hydrostatic reduction was not performed by an experienced sonologist (p < 0.01). The presence of free peritoneal fluid was not a predictor of outcome (p > 0.1). No complications during or after hydrostatic enema were noted.Conclusions.: Sonographically guided hydrostatic reduction of intussusception is safe and effective. We recommend that this method be attempted before surgery is considered, even in cases in which the intussusception contains entrapped fluid or is located in the left side of the abdomen. The level of experience of the radiologist who performs the reduction significantly affects the results of this procedure and should be carefully considered, particularly in cases in which initial sonography reveals the presence of risk factors. © 2002 Wiley Periodicals, Inc. J Clin Ultrasound 30: 343–348, 2002; Published online in Wiley InterScience (www.interscience.wiley.com). DOI: 10.1002/jcu.10085Keywords
This publication has 28 references indexed in Scilit:
- Effective Dose at Pneumatic Reduction of Paediatric IntussusceptionClinical Radiology, 2000
- Hydrostatic reduction of intussusception under US guidancePediatric Radiology, 1995
- Why i still use barium for intussusceptionPediatric Radiology, 1995
- Childhood intussusception and approaches to treatment: A historical reviewPediatric Radiology, 1994
- Ultrasonography is accurate enough for the diagnosis of intussusceptionJournal of Pediatric Surgery, 1994
- Pneumatic reduction of intussusception: Clinical experience and factors affecting outcomeClinical Radiology, 1994
- Gas enema for the reduction of intussusception: relationship between clinical signs and symptoms and outcome.American Journal of Roentgenology, 1993
- Clinical application of ultrasonography in the diagnosis of intussusceptionThe Journal of Pediatrics, 1992
- Intussusception: clinical and radiographic factors influencing reducibilityPediatric Radiology, 1989
- Enema reduction of intussusception by hydrostatic pressure under ultrasound guidance: A report of 377 casesJournal of Pediatric Surgery, 1988