Analysis of organic components of smokeless gunpowders: High‐performance liquid chromatogaphyvs.micellar electrokinetic capillary chromatography
Authors:
- 2 June 2004
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 25 (10-11) , 1543-1547
Abstract
The aim of the present study was to verify the analytical performances of high‐performance liquid chromatography (HPLC) and micellar electrokinetic capillary chromatography (MEKC) for the separation and qualitative determination of a selected group of organic components of smokeless gunpowders. The HPLC method was based on a gradient reversed‐phase elution with a mobile phase composed of 0.17 MH3PO4/methanol; detection was performed by UV absorption at the wavelengths of 220, 254, and 270 nm. The MEKC experiments were carried out by using uncoated fused‐silica capillaries (50 μm inside diameter, 50 cm effective length) and a running buffer composed of 10 mMsodium tetraborate at pH 9.24 added with 25 mMsodium dodecyl sulfate (SDS); the applied voltage was 25 kV; detection was either at a fixed wavelength UV of 214 nm or with a diode‐array detector operating in the wavelength range from 190 to 350 nm. Both reversed‐phase HPLC and MEKC techniques succeeded in resolving the tested standard mixtures of organic components of smokeless powders. Although the sequence of elution of the different analytes was slightly different between HPLC and MEKC, a statistical analysis based on the Spearman's rank correlation test showed that the two separation patterns were highly correlated. HPLC and MEKC were comparable in terms of elution/migration time precision, whereas MEKC showed higher reproducibility of peak areas. The interfacing of capillary electrophoresis with diode array UV detection provided distinct UV spectra of the individual analytes, thus improving, on the detection side, the analytical selectivity and identification power of capillary electrophoresis.Keywords
This publication has 13 references indexed in Scilit:
- Optimization of the Separation of Organic Explosives by Capillary Electrophoresis with Artificial Neural NetworksJournal of Forensic Sciences, 2003
- A Gradient Reversed Phase HPLC Procedure for Smokeless Powder ComparisonJournal of Forensic Sciences, 2002
- Investigating the Effect of Changing Ammunition on the Composition of Organic Additives in Gunshot Residue (OGSR)Journal of Forensic Sciences, 2001
- Comparing the Additive Composition of Smokeless Gunpowder and Its Handgun-fired ResiduesJournal of Forensic Sciences, 2000
- Forensic capillary electrophoresisTrAC Trends in Analytical Chemistry, 1996
- Characterization of smokeless gunpowder by means of diphenylamine stabilizer and its nitrated derivativesAnalytica Chimica Acta, 1994
- Separation and identification of organic gunshot and explosive constituents by micellar electrokinetic capillary electrophoresisAnalytical Chemistry, 1991
- Micellar electrokinetic capillary chromatography of illicit drug substancesAnalytical Chemistry, 1991
- Gunshot residue analysis via organic stabilizers and nitrocelluloseMicrochemical Journal, 1989
- Separation and identification of minor components in smokeless powders by thin-layer chromatographyJournal of Chromatography A, 1975