A novel total knee arthroplasty infection model in rabbits
Authors:
- Thomas E. BrownTBThomas E. Brown
- 1 September 2005
- journal article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 23 (5) , 1100-1104
Abstract
Infection of biomaterial implants is an expensive and devastating complication of orthopaedic surgery historically ranging from less than 1% in primary total knee arthroplasty (TKA) to 10% in revision TKA. An in vivo animal model was developed to test the efficacy of innovative therapies for the prevention of biomaterial centered infections caused by methicillin‐resistant Staphylococcus aureus bacteria (MRSA). Twenty‐two New Zealand White rabbits were used in this study. After proper anesthesia, a stainless‐steel screw with a high molecular weight polyethylene (UHMWPE) washer was cemented in a defect created in the intra‐articular, nonarticulating portion of the lateral femoral condyle of each knee. After closure of the joint capsule, each knee was inoculated with 0, 102, 103, or 104 colony forming units (CFU) of MRSA. Animals were sacrificed after 7 days at which time joint aspirate, tissues and biomaterial samples were examined for evidence of infection.A total of 42 knees were used for analysis. When saline was injected into the knee, 0/10 of the knees demonstrated evidence of biomaterial centered infection (with the contralateral knee receiving 104 CFU MRSA). Four of 10 knees developed a biomaterial centered infection when 102 CFU MRSA was introduced. Seven out of 10 knees developed a biomaterial centered infection when either 103 or 104 CFU MRSA was injected. No evidence of septicemia (positive blood cultures) was found in any animal. This rabbit knee model utilizes commonly employed inexpensive orthopaedic implant materials in an in vivo milieu and provides an effective method for the evaluation of treatments for biomaterial centered infections. © 2005 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.Keywords
This publication has 19 references indexed in Scilit:
- Prevention and control of methicillin-resistant Staphylococcus aureus infectionsCurrent Opinion in Infectious Diseases, 2004
- Results of Periprosthetic Hip and Knee Infections Caused by Resistant BacteriaClinical Orthopaedics and Related Research, 2002
- Early Failures in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2001
- Infection in Total Knee ReplacementClinical Orthopaedics and Related Research, 2001
- A Novel Spinal Implant Infection Model in RabbitsSpine, 2000
- Experimental Models of Bone and Prosthetic Joint InfectionsClinical Infectious Diseases, 1997
- The Prevention of Prosthetic Infection Using a Cross-Linked Albumin in a Rabbit ModelThe Journal of Bone and Joint Surgery. British volume, 1997
- A New Model of Experimental Prosthetic Joint Infection Due to Methicillin-Resistant Staphylococcus aureus: A Microbiologic, Histopathologic, and Magnetic Resonance Imaging CharacterizationThe Journal of Infectious Diseases, 1996
- INFLUENCE OF MATERIALS FOR FIXATION IMPLANTS ON LOCAL INFECTIONThe Journal of Bone and Joint Surgery. British volume, 1996
- Revision after Total Knee ArthroplastyOrthopedic Clinics of North America, 1982