In vivo sodium imaging of human patellar cartilage with a 3D cones sequence at 3 T and 7 T
Open Access
- 22 July 2010
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 32 (2) , 446-451
Abstract
Purpose: To compare signal‐to‐noise ratios (SNRs) and T*2 maps at 3 T and 7 T using 3D cones from in vivo sodium images of the human knee.Materials and Methods: Sodium concentration has been shown to correlate with glycosaminoglycan content of cartilage and is a possible biomarker of osteoarthritis. Using a 3D cones trajectory, 17 subjects were scanned at 3 T and 12 at 7 T using custom‐made sodium‐only and dual‐tuned sodium/proton surface coils, at a standard resolution (1.3 × 1.3 × 4.0 mm3) and a high resolution (1.0 × 1.0 × 2.0 mm3). We measured the SNR of the images and the T*2 of cartilage at both 3 T and 7 T.Results: The average normalized SNR values of standard‐resolution images were 27.1 and 11.3 at 7 T and 3 T. At high resolution, these average SNR values were 16.5 and 7.3. Image quality was sufficient to show spatial variations of sodium content. The average T*2 of cartilage was measured as 13.2 ± 1.5 msec at 7 T and 15.5 ± 1.3 msec at 3 T.Conclusion: We acquired sodium images of patellar cartilage at 3 T and 7 T in under 26 minutes using 3D cones with high resolution and acceptable SNR. The SNR improvement at 7 T over 3 T was within the expected range based on the increase in field strength. The measured T*2 values were also consistent with previously published values. J. Magn. Reson. Imaging 2010;32:446–451.Keywords
This publication has 20 references indexed in Scilit:
- Exploring the limits of RF shimming for high‐field MRI of the human headMagnetic Resonance in Medicine, 2006
- B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coilMagnetic Resonance in Medicine, 2005
- Proteoglycan Loss in Human Knee Cartilage: Quantitation with Sodium MR Imaging—Feasibility StudyRadiology, 2004
- Simple Correction Method fork-Space Trajectory Deviations in MRIJournal of Magnetic Resonance, 1998
- Sodium MRI of human articular cartilage in vivoMagnetic Resonance in Medicine, 1998
- MRI using piecewise-linear spiral trajectoryMagnetic Resonance in Medicine, 1997
- Fast Three Dimensional Magnetic Resonance ImagingMagnetic Resonance in Medicine, 1995
- Fat-suppressed spoiled GRASS imaging of knee hyaline cartilage: technique optimization and comparison with conventional MR imaging.American Journal of Roentgenology, 1994
- MR imaging of articular cartilage: current status and future directions.American Journal of Roentgenology, 1994
- Noise performance of surface coils for magnetic resonance imaging at 1.5 TMedical Physics, 1985