Abstract
Seismic design codes assign response modification factors (R-factors) primarily by structural-system type. This study examines how the calculated seismic response changes when the prescribed column longitudinal reinforcement level is varied together with the member redesign required by the adopted design procedure. The database comprises 432 reinforced-concrete configurations: 216 moment-resisting frames and 216 dual systems. Prescribed reinforcement levels of 1–4%, structural height, bay number, beam configuration, and column-base condition were varied. Nonlinear static pushover analysis was used to evaluate the N2-based R-factor, and selected configurations were examined by progressively scaled nonlinear response-history analyses as a dynamic trend check. From 1% to 4% prescribed reinforcement, the associated redesign increased the fundamental period by up to about 140% for moment-resisting frames, with the dual-system configurations showing the same direction of change, while the pushover-based R-factor decreased by up to about 40% and 35%, respectively. The proposed relationships are descriptive summaries of the investigated redesign scenarios; they are not independently validated design modifiers and do not provide a basis for changing code-prescribed R-values. These R-values are numerical estimates obtained within the adopted modelling and analysis framework, characterizing relative trends across the investigated configurations rather than general values for reinforced-concrete systems.

This publication has 15 references indexed in Scilit: