Potentiometric Sensors in the Wild: Long-Term Stability, Biofouling, and Calibration Strategies for Environmental Applications
Open Access
Abstract
Potentiometric ion-selective electrodes (ISEs) are attractive tools for environmental monitoring, enabling simple, rapid, and continuous measurements directly at the sampling site. However, their long-term operation under real environmental conditions remains challenging. While laboratory studies focus on sensitivity, selectivity, and detection limits, prolonged deployment introduces potential drift, water-layer formation, membrane-component leaching, fouling, biofouling, and instability of the reference electrode. These effects alter sensor response and compromise measurement reliability without causing immediate failure. This review discusses mechanisms responsible for sensor degradation during in situ operation and summarizes material- and system-level strategies for improving long-term stability. Particular attention is given to antifouling approaches, calibration strategies, drift compensation, and methods for evaluating sensor condition, including electrochemical impedance spectroscopy, water-layer tests, and surface characterization. Recent developments toward self-calibrating, calibration-free, and autonomous potentiometric platforms are also discussed. Finally, current limitations and future directions are considered, emphasizing the need for standardized long-term testing, validation in real environmental matrices, integrated diagnostics, and reliable operation of the complete cell to maintain measurement reliability throughout deployment.Keywords
Funding Information
- Minister of Science and Higher Education
- AGH University of Krakow
This publication has 142 references indexed in Scilit:
- Design Criteria for Nanostructured Carbon Materials as Solid Contacts for Ion‐Selective SensorsAdvanced Materials, 2023
- Water quality monitoring in recirculating aquaculture systemsAquaculture, Fish and Fisheries, 2023
- Potentiometric Sensor for the Ion Speciation in the Industrial Waters2022
- Evaluation, Pitfalls and Recommendations for the “Water Layer Test” for Solid Contact Ion‐selective ElectrodesElectroanalysis, 2019
- Effects of type of nanosized carbon black on the performance of an all-solid-state potentiometric electrode for nitrateMicrochimica Acta, 2014
- Composite Carbon Nanotube/Carbon Electrodes for Electrical Double‐Layer Super CapacitorsAngewandte Chemie, 2012
- The Water Uptake of Plasticized Poly(vinyl chloride) Solid‐Contact Calcium‐Selective ElectrodesElectroanalysis, 2011
- Modern PotentiometryAngewandte Chemie International Edition, 2007
- Conducting Polymer‐Based Solid‐State Ion‐Selective ElectrodesElectroanalysis, 2006
- Potential Drifts of Solid-Contacted Ion-Selective Electrodes Due to Zero-Current Ion Fluxes Through the Sensor MembraneElectroanalysis, 2000