Bone contact, growth, and density around immediately loaded implants in the mandible of mini pigs
Authors:
- Emeka NkenkeENEmeka Nkenke
- Bernhard LehnerBLBernhard Lehner
- Konstanze WeinzierlKWKonstanze Weinzierl
- Ulf ThamsUTUlf Thams
- Jörg NeugebauerJNJörg Neugebauer
- Helmut StevelingHSHelmut Steveling
- Martin Radespiel‐TrögerMRMartin Radespiel‐Tröger
- Friedrich Wilhelm NeukamFNFriedrich Wilhelm Neukam
- 20 May 2003
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 14 (3) , 312-321
Abstract
The aim of the study was to compare the bone mineral apposition rate (BMAR) of immediately loaded implants with an unloaded control during the early healing phase in the partially edentulous mandible. In seven mini pigs, three premolars and the first molar were removed in the left mandible. Three months later, five implants were installed. Four implants received a fixed provisional restoration and were loaded immediately. The most anterior implant was used as unloaded control. Polychromatic fluorescence labelling was performed to assess the BMAR. After 4 months, the implants were retrieved together with the adjacent bone. Histological specimens were prepared and subjected to a fluorescence microscopic and histomorphometric analysis. Two provisional restorations were found partially lost at the end of the observation period. One implant that had lost the splinting fixation showed soft connective tissue healing. The BMAR did not differ statistically significantly between loaded and unloaded implants and within the single groups during the observation period (BMARloaded days 14−42=1.8±0.2 μm/d, BMARloaded days 42−70=1.8±0.1 μm/d, BMARloaded days 70−98=1.6±0.1 μm/d, pBMARloaded days 14–42/42–70/70–98=0.156, BMARunloaded days 14−42=1.7±0.1 μm/d, BMARunloaded days 42−70=1.8±0.2 μm/d, BMARunloaded days 70−98=1.6±0.4 μm/d, pBMARunloaded days 14–42/42–70/70–98=0.368, pBMARloaded/unloaded days 14–42=0.073, pBMARloaded/unloaded days 42–70=0.098, pBMARloaded/unloaded days 70–98=0.262). Four months after implant placement, the bone‐to‐implant contact was 77.8±17.3% for the loaded and 78.0±5.8% for the unloaded implants (P=0.753). Immediate loading does not affect the bone mineral apposition rate when compared with unloaded implants. Rigid splinting seems to be the crucial factor for implant success. Uncontrolled masticatory forces can cause failure after partial loss of the provisional restoration.Keywords
This publication has 25 references indexed in Scilit:
- Peri‐Implant Bone Reactions to Immediately Loaded Implants. An Experimental Study in MonkeysJournal of Periodontology, 2001
- Histological observations on biopsies harvested following sinus floor elevation using a bioactive glass material of narrow size rangeClinical Oral Implants Research, 2000
- Immediate Loading of Implants in Partially and Fully Edentulous Jaws: A Series of 27 Case ReportsJournal of Periodontology, 2000
- Immediate functional loading of Brånemark dental implants. An l8‐month clinical follow‐up studyClinical Oral Implants Research, 1999
- Implant‐retained mandibular overdentures with immediate loadingClinical Oral Implants Research, 1997
- Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits.Clinical Oral Implants Research, 1996
- Perspectives: The role of changes in mechanical usage set points in the pathogenesis of osteoporosisJournal of Bone and Mineral Research, 1992
- Biomechanical factors affecting the bone-dental implant interfaceClinical Materials, 1992
- A method for the study of undecalcified bones and teeth with attached soft tissues*Journal of Oral Pathology & Medicine, 1982
- Osseointegrated Titanium Implants:Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Anchorage in ManActa Orthopaedica, 1981