In vitro analysis of intraoral digital impression of inlay preparation according to tooth location and cavity type
Authors:
Open Access
- 1 January 2021
- journal article
- research article
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 65 (3) , 400-406
Abstract
Purpose: This study aimed to evaluate the influence of tooth location and inlay cavity type on the accuracy of intraoral digital impressions. Methods: Class II inlay preparation was performed on anatomical models of the maxillary first molar (16) and mandibular first molar (46). Mesio-occlusal and disto-occlusal cavities were prepared, such that the axial wall of the proximal box measured 1 mm or 2 mm in height. Thus, four types of inlay cavities were prepared in 16 and 46, respectively. Ten digital impressions of each cavity were obtained using Cerec Primescan (Sirona). Reference scans were obtained with a laboratory scanner (E3, 3Shape). All scan data were exported for comparative analysis of the three-dimensional models. Mean absolute deviation values were calculated to evaluate the trueness and precision of the digital models. Color-coded maps were used for the qualitative analysis of deviations. Results: The overall results showed that the trueness for 16 (10.43 ± 0.39 μm) was higher than that for 46 (12.42 ± 0.59 μm) (p < 0.05), while the precision was similar between 16 (3.08 ± 0.92 μm) and 46 (3.08 ± 0.76 μm). The cavity type affected the accuracy of the digital impressions. The highest deviation was observed in positive directions at the margins of the proximal boxes regardless of the cavity type. Conclusions: Tooth location and cavity type affected the accuracy of intraoral digital impressions. Positive deviations were observed at the margins of the proximal boxes.Keywords
This publication has 28 references indexed in Scilit:
- A new method for the evaluation of the accuracy of full-arch digital impressions in vitroClinical Oral Investigations, 2015
- Comparison of repeatability between intraoral digital scanner and extraoral digital scanner: An in-vitro studyJournal of Prosthodontic Research, 2015
- Influence of material surface on the scanning error of a powder-free 3D measuring systemClinical Oral Investigations, 2015
- Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patientsClinical Oral Investigations, 2015
- Influence of preparation design on fit and ceramic thickness of CEREC 3 partial ceramic crowns after cementationActa Odontologica Scandinavica, 2014
- Digital vs. conventional implant prosthetic workflows: a cost/time analysisClinical Oral Implants Research, 2014
- Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scannerAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2013
- Marginal Gap, Internal Fit, and Fracture Load of Leucite-Reinforced Ceramic Inlays Fabricated by CEREC inLab and Hot-Pressed TechniquesJournal of Prosthodontics, 2011
- Dental CAD/CAM systemsThe Journal of the American Dental Association, 2006
- The estimation of cement film thickness by an in vivo techniqueBritish Dental Journal, 1971