Misleading HbA1c Measurement in Diabetic Patients with Hemoglobin Variants
Open Access
- 7 June 2021
- journal article
- research article
- Published by MDPI AG in Medical Sciences
- Vol. 9 (2) , 43
Abstract
Background and Objectives: Hemoglobin A1c (HbA1c) is widely used for the monitoring and management of diabetes mellitus. The aim of this study is to investigate the influence of hemoglobin (Hb) variants on the measurement of HbA1c. Materials and Methods: HbA1c levels of 845 blood samples obtained from diabetic patients with various hemoglobin types were measured using a turbidimetric inhibition immunoassay and capillary electrophoresis. Results: Of 845 patients with diabetes, 65.7% (555/845) have the normal hemoglobin type (A2A) and 34.3% (290/845) have various abnormal hemoglobin types, including heterozygous HbE 30.2% (255/845), homozygous HbE 1.9 % (16/845), Hb Constant Spring (CS) trait 1.4% (12/845), CSEA Bart’s 0.2% (2/845), and beta-thalassemia trait 0.6% (5/845). In most of the patients with diabetes, HbA1c levels determined by two different methods, inhibition immunoassay and capillary electrophoresis, gave strong positive correlation (R = 0.901, P < 0.001), except for those with homozygous HbE (N = 16) and CSEA Bart’s (N = 2). In all 18 patients with homozygous HbE and CSEA Bart’s, the HbA1c was undetectable by capillary electrophoresis, meaning that their estimated average glucose was undeterminable, although their HbA1c levels could be measured using an inhibition immunoassay. The discrepancy of HbA1c results obtained from two different methods is noted in patients without HbA. Conclusions: We have demonstrated the erroneous nature of HbA1c measurement in patients with hemoglobin variants, especially in those without HbA expression. Therefore, in the population with a high prevalence of hemoglobinopathies, hemoglobin typing should be considered as basic information prior to HbA1c measurement.Keywords
Funding Information
- Association of Medical Technologists of Thailand (2563-004)
This publication has 21 references indexed in Scilit:
- Effects of 49 Different Rare Hb Variants on HbA1c Measurement in Eight MethodsJournal of Diabetes Science and Technology, 2015
- Performances of Capillary Electrophoresis and HPLC Methods in HbA1c Determination: Diagnostic Accuracy in HbS and HbD‐Iran Variants' PresenceJournal of Clinical Laboratory Analysis, 2014
- HbA1c: A Review of Analytical and Clinical AspectsAnnals of Laboratory Medicine, 2013
- HbA1c: performance of the Sebia Capillarys 2 Flex PiercingClinical Chemistry and Laboratory Medicine (CCLM), 2012
- World Distribution, Population Genetics, and Health Burden of the HemoglobinopathiesCold Spring Harbor Perspectives in Medicine, 2012
- Translating the A1C Assay Into Estimated Average Glucose ValuesDiabetes Care, 2008
- Standards of Medical Care in Diabetes—2008Diabetes Care, 2008
- α⁰-Thalassemia and Related Disorders in Northeast Thailand: A Molecular and Hematological CharacterizationActa Haematologica, 2006
- Effects of Hemoglobin C and S Traits on Glycohemoglobin Measurements by Eleven MethodsClinical Chemistry, 2005
- Hemoglobin Variants and Hemoglobin A1c Analysis: Problem Solved?Clinical Chemistry, 2003