FengYun-3 B Satellite Medium Resolution Spectral Imager Visible On-Board Calibrator Radiometric Output Degradation Analysis
- 14 December 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 57 (6) , 3240-3251
Abstract
The output of the FengYun-3 B (FY-3B) satellite's medium resolution spectral imager (MERSI) visible on-board calibrator (OBC) degrades with time, causing concerns regarding its reliability in radiometric calibration. Special efforts have been made to extract the variation in information of the interior lamps. The specifications include: 1) digital count retrieval from the OBC files and an exponential plus linear fit applied to determine the relative change in the MERSI response; 2) anchoring to cross calibration with MODIS to acquire the absolute radiometric calibration coefficients; 3) a time series calibration tracking method based on the pseudoinvariant target site applied to monitor the degradation of the FY-3B MERSI instrument; and 4) “net” interior lamp radiometric output (ILRO) obtained by subtracting long-term pseudoinvariant tracking results from the scaled visible on-board calibrator-based model gain coefficients. The results show that the decay rates of the ILRO are wavelength dependent and the shortwave outputs are found to experience a large degradation, particularly at 470, 550, 412, 443, 490, 520, and 565 nm. The largest annual degradation rate is greater than 15% in the first year. The implementation of the current procedure combined with a detailed analysis will provide a basis for further determining lamp changes, leading to improved absolute calibration accuracy of MERSI products.Keywords
Funding Information
- Civil Aerospace Technology Advance Research Project (D040401)
- Chinese Academy of Sciences (6141A01011602)
- National Natural Science Foundation of China (41471303)
This publication has 17 references indexed in Scilit:
- Cross-Calibration of HJ-1/CCD Over a Desert Site Using Landsat ETM $+$ Imagery and ASTER GDEM ProductIEEE Transactions on Geoscience and Remote Sensing, 2014
- Calibration for the Solar Reflective Bands of Medium Resolution Spectral Imager Onboard FY-3AIEEE Transactions on Geoscience and Remote Sensing, 2012
- Long-term calibration monitoring of medium resolution spectral imager (MERSI) solar bands onboard FY-32012
- Multisite Calibration Tracking for FY-3A MERSI Solar BandsIEEE Transactions on Geoscience and Remote Sensing, 2012
- Radiometric Calibration of the Landsat MSS Sensor SeriesIEEE Transactions on Geoscience and Remote Sensing, 2011
- Updated Radiometric Calibration for the Landsat-5 Thematic Mapper Reflective BandsIEEE Transactions on Geoscience and Remote Sensing, 2008
- A new method for cross-calibration of two satellite sensorsInternational Journal of Remote Sensing, 2004
- Comparison of MODIS and AVHRR 16‐day normalized difference vegetation index composite dataGeophysical Research Letters, 2004
- Radiometric cross-calibration of the Landsat-7 ETM+ and Landsat-5 TM sensors based on tandem data setsRemote Sensing of Environment, 2001
- Post-launch calibration of the visible and near-infrared channels of the Advanced Very High Resolution Radiometer on the NOAA-14 spacecraftInternational Journal of Remote Sensing, 1996