Influence of the contact model on the dynamic response of the human knee joint
- 29 September 2011
- journal article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part K: Journal of Multi-Body Dynamics
- Vol. 225 (4) , 344-358
Abstract
The goal of this work is to study the influence of the contact force model, contact geometry, and contact material properties on the dynamic response of a human knee joint model. For this purpose, a multibody knee model composed by two rigid bodies, the femur and the tibia, and four non-linear spring elements that represent the main knee ligaments, is considered. The contact force models used were the Hertz, the Hunt–Crossley, and the Lankarani–Nikravesh approaches. Results obtained from computational simulations show that Hertz law is less suitable to describe the dynamic response of the cartilage contact, because this pure elastic model does not account for the viscoelastic nature of the human articulations. Since knee can exhibit conformal and non-conformal contact scenarios, three different geometrical configurations for femur–tibia contact are considered, that is convex–convex sphere contact, convex–concave sphere contact, and convex sphere–plane contact. The highest level of contact forces is obtained for the case of convex–convex sphere contact. As far as the influence of the material contact properties is concerned, the dynamic response of a healthy and natural knee is analysed and compared with three pathological and two artificial knee models. The obtained results demonstrate that the presence of the cartilage reduces significantly the knee contact forces.Keywords
This publication has 66 references indexed in Scilit:
- Comparison Between Elastic Foundation and Contact Force Models in Wear Analysis of Planar Multibody SystemJournal of Tribology, 2010
- Modeling and simulation of wear in revolute clearance joints in multibody systemsMechanism and Machine Theory, 2009
- Normal Force-Displacement Relationship of Spherical Joints With ClearancesJournal of Computational and Nonlinear Dynamics, 2005
- An anatomically based patient-specific finite element model of patella articulation: towards a diagnostic toolBiomechanics and Modeling in Mechanobiology, 2005
- Literature survey of contact dynamics modellingMechanism and Machine Theory, 2002
- A Three-Dimensional Musculoskeletal Model of the Human Knee Joint. Part 1: Theoretical ConstructionComputer Methods in Biomechanics and Biomedical Engineering, 1997
- A Two-Dimensional Dynamic Anatomical Model of the Human Knee JointJournal of Biomechanical Engineering, 1993
- Improved Dynamic Model of the Human Knee Joint and Its Response to Impact Loading on the Lower LegJournal of Biomechanical Engineering, 1993
- A Contact Force Model With Hysteresis Damping for Impact Analysis of Multibody SystemsJournal of Mechanical Design, 1990
- Coefficient of Restitution Interpreted as Damping in VibroimpactJournal of Applied Mechanics, 1975