Seismic Performance of Frame Structure with Hysteretic Intermediate Discontinuity
Open Access
- 25 April 2023
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 13 (9) , 5373
Abstract
The introduction of an intermediate discontinuity in frame structures is commonly named inter-storey isolation. Inter-storey isolation is an effective technique for the seismic protection of new or existing frame structures. The devices that are used to perform the discontinuity, mainly of the structural stiffness, are placed at a higher storey level of the structure and not at the base level. In the latter years, this technique has gained increasing interest because, especially for existing buildings, it is cheaper and technically easier to implement than base isolation. In this paper, the attention is focused on the effects on a frame structure of an intermediate elasto-plastic discontinuity that can be described by a Bouc-Wen model. The frame structure with the intermediate discontinuity is modelled with a 3-DOF reduced model. Its dynamical behaviour is investigated by considering both harmonic and seismic external excitation. The results are summarized in gain maps aimed at finding the parameters that optimize the seismic behaviour of the structure.Keywords
Funding Information
- CARISPAQ Foundation
This publication has 29 references indexed in Scilit:
- Dynamic behavior of a building structure tested with base and mid-story isolation systemsEngineering Structures, 2012
- Dynamic response and optimal design of structures with large mass ratio TMDEarthquake Engineering & Structural Dynamics, 2011
- Robust design of mass-uncertain rolling-pendulum TMDs for the seismic protection of buildingsMechanical Systems and Signal Processing, 2009
- Effect of tuned mass damper on displacement demand of base-isolated structuresEngineering Structures, 2008
- On tuned mass dampers for reducing the seismic response of structuresEarthquake Engineering & Structural Dynamics, 2005
- Parameter Analysis of the Differential Model of HysteresisJournal of Applied Mechanics, 2004
- Parametric study and simplified design of tuned mass dampersEngineering Structures, 1998
- A METHOD OF ESTIMATING THE PARAMETERS OF TUNED MASS DAMPERS FOR SEISMIC APPLICATIONSEarthquake Engineering & Structural Dynamics, 1997
- Vibration Control of Tall Buildings Using Mega SubConfigurationJournal of Engineering Mechanics, 1995
- The effect of tuned-mass dampers on the seismic response of base-isolated structuresInternational Journal of Solids and Structures, 1995