Refractive precision in uncomplicated eyes with pseudoexfoliation: three‐piece versus one‐piece intraocular lens implantation
- 7 January 2021
- journal article
- research article
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (6) , 616-620
Abstract
Purpose: To evaluate the refractive precision of three‐piece versus one‐piece intraocular lenses (IOLs) in eyes with pseudoexfoliation (PXF) and changes in anterior chamber depth (ACD) following cataract surgery.Methods: This prospective, nonrandomized, interventional, comparative case series included PXF eyes, which were implanted with one‐piece acrylic IOL or three‐piece acrylic IOLs (Group A; n = 31, Group B; n = 30). Non‐PXF control eyes were implanted with one‐piece acrylic IOL (Group C; n = 30). Postoperative refractive error (RE) and absolute RE, as well as pre‐ to postoperative ACD changes, were statistically analysed. A p value < 0.05 was considered statistically significant.Results: Changes in ACD (mean ± standard deviation) in Groups A, B and C were 0.9 ± 0.4, 1.0 ± 0.3 and 0.7 ± 0.4 mm, respectively. Significant differences were found between Groups A and C (p = 0.043) and between Groups B and C (p = 0.008). In Groups A, B and C, the median and interquartile (Q1 to Q3) values were 0.3 (−0.8 to 1.0), −0.5 (−0.8 to −0.3) and 0.1 (−0.4 to 0.3) for RE and 1.0 (0.4 to 1.3), 0.5 (0.3 to 0.8) and 0.3 (0.3 to 0.5) for absolute RE, respectively. The RE differences between Group A and B (p = 0.009) and Group B and C (p < 0.001) were statistically significant. For absolute RE, the differences were significant for all comparisons (p < 0.05).Conclusion: Refractive precision in PXF eyes may be better with three‐piece than with one‐piece IOL implantation, but worse than with one‐piece IOL implantation in non‐PXF eyes. Significant changes in ACD in PXF eyes may be related to RE.Keywords
This publication has 23 references indexed in Scilit:
- Pseudoexfoliation and the cataract surgeon: Preoperative, intraoperative, and postoperative issues related to intraocular pressure, cataract, and intraocular lensesJournal of Cataract & Refractive Surgery, 2009
- Sources of error in intraocular lens power calculationJournal of Cataract & Refractive Surgery, 2008
- Common Sequence Variants in the LOXL1 Gene Confer Susceptibility to Exfoliation GlaucomaScience, 2007
- Ocular and Systemic Pseudoexfoliation SyndromeAmerican Journal of Ophthalmology, 2006
- Effect of haptic design on change in axial lens position after cataract surgeryJournal of Cataract & Refractive Surgery, 2004
- Pseudoexfoliation syndrome for the comprehensive ophthalmologist Intraocular and systemic manifestationsHistorical imageOphthalmology, 1998
- The Blood-Aqueous Barrier in Eyes with Pseudoexf oliation SyndromeOphthalmic Research, 1995
- Corneal Endothelial Involvement in Pseudoexfoliation SyndromeArchives of Ophthalmology (1950), 1993
- Pseudoexfoliative Fibrillopathy in Visceral Organs of a Patient With Pseudoexfoliation SyndromeArchives of Ophthalmology (1950), 1992
- Pseudoexfoliation Syndrome Ocular Manifestation of a Systemic Disorder?Archives of Ophthalmology (1950), 1992