The dramatic growth of power electronics applications has led to serious harmonic pollutions in the power system. The phenomenon of harmonic resonance resulting in severe voltage distortion has been reported. Various suppression techniques have been proposed to resolve this problem. Single termination active filter, whether operating with a constant conductance command or an automatically tuned conductance command, fail to suppress the harmonic resonance effectively and the voltage distortion may still be severe along the radial line. This paper proposes a capacity tuning scheme for the distributed active filter systems (DAFS) to enhance the harmonic filtering performance. Based on the measured voltage THD at the installation point, the active filter can dynamically adjusts its filtering capacity to maintain the voltage THD at a desired level. The proposed strategy can be integrated with the droop control between the conductance command and volt-ampere consumption so that the harmonic filtering workload is evenly shared among various active filter units of the DAFS. The operation principle is explained in this paper and test results based on simulation and experiment are provided to validate the proposed tuning schemeKeywords
This publication has 7 references indexed in Scilit:
- Analysis of Harmonic Damping Effect of the Distributed Active Filter SystemIEEJ Transactions on Industry Applications, 2006
- Design of a new cooperative harmonic filtering strategy for the distributed generation systems2005
- Implementation and performance of cooperative control of shunt active filters for harmonic damping throughout a power distribution systemIEEE Transactions on Industry Applications, 2003
- Considerations of a shunt active filter based on voltage detection for installation on a long distribution feederIEEE Transactions on Industry Applications, 2002
- Implementation and performance of automatic gain adjustment in a shunt-active filter for harmonic damping throughout a power distribution systemIEEE Transactions on Power Electronics, 2002
- A shunt active filter based on voltage detection for harmonic termination of a radial power distribution lineIEEE Transactions on Industry Applications, 1999
- Harmonic resonance at a medium-sized industrial plantIEEE Transactions on Industry Applications, 1995