Characteristics of pulsed electric field cardiac ablation porcine treatment zones with a focal catheter
Authors:
Open Access
- 16 November 2022
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 34 (1) , 99-107
Abstract
Objectives: Pulsed electric field (PEF) therapies employ punctuated energy delivery to kill cells in a volume of tissue through mechanisms that are not dependent on thermal processes. A key component to successful cardiac ablation procedures is ensuring the generation of transmural, contiguous ablation zones, which requires in‐depth knowledge regarding treatment sizes for a given therapeutic application.Methods: In this study, a series of acute treatments were delivered to porcine ventricles, where triphenyl tetrazolium chloride (TTC) vitality stain was used to identify treatment effect sizes for the three focal monopolar CENTAURI PEF cardiac ablation energy settings.Results: Treatment depths were 5.7, 7.2, and 8.2 mm for the 19, 22, and 25 A energy settings, respectively. Gross pathology indicated umbral zones of hemorrhage surrounded by pale avital TTC‐negative‐negative tissue, which contrasted significantly from radiofrequency ablation (RF) controls. Histologically, treatment zones are identified by regions of contraction band necrosis and cardiomyocytolysis, which contrasted with RF control lesions composed primarily of coagulation necrosis.Conclusions: Together, these data indicate the ability for focal monopolar PEF treatments to generate deep treatment zones in cardiac ablation without incurring the gross or histological coagulative characteristics of RF thermal lesions.Keywords
This publication has 31 references indexed in Scilit:
- Endocardial Versus Epicardial Ventricular Radiofrequency AblationCirculation: Arrhythmia and Electrophysiology, 2013
- Normal Left Ventricular Myocardial Thickness for Middle-Aged and Older Subjects With Steady-State Free Precession Cardiac Magnetic ResonanceCirculation: Cardiovascular Imaging, 2012
- Myocardial Lesion Depth With Circular Electroporation AblationCirculation: Arrhythmia and Electrophysiology, 2012
- Minimal coronary artery damage by myocardial electroporation ablationEP Europace, 2012
- US Findings after Irreversible Electroporation Ablation: Radiologic-Pathologic CorrelationRadiology, 2012
- Characterization of Irreversible Electroporation Ablation in In Vivo Porcine LiverAmerican Journal of Roentgenology, 2012
- High-frequency irreversible electroporation (H-FIRE) for non-thermal ablation without muscle contractionBioMedical Engineering OnLine, 2011
- The Effects of Irreversible Electroporation (IRE) on NervesPLOS ONE, 2011
- Thermal Damage and Rate Processes in Biologic Tissues2010
- Right Atrial Cavotricuspid Isthmus: Anatomic Characterization with Multi–Detector Row CTRadiology, 2008