Design, Manufacture, and Characterization of a Critical-Sized Gradient Porosity Dual-Material Tibial Defect Scaffold
Open Access
- 25 March 2024
- journal article
- research article
- Published by MDPI AG in Bioengineering
- Vol. 11 (4) , 308
Abstract
This study proposed a composite tibia defect scaffold with radial gradient porosity, utilizing finite element analysis to assess stress in the tibial region with significant critical-sized defects. Simulations for scaffolds with different porosities were conducted, designing an optimal tibia defect scaffold with radial gradient porosity for repairing and replacing critical bone defects. Radial gradient porosity scaffolds resulted in a more uniform stress distribution, reducing titanium alloy stiffness and alleviating stress shielding effects. The scaffold was manufactured using selective laser melting (SLM) technology with stress relief annealing to simplify porous structure fabrication. The study used New Zealand white rabbits’ tibia defect sites as simulation parameters, reconstructing the 3D model and implanting the composite scaffold. Finite element analysis in ANSYS-Workbench simulated forces under high-activity conditions, analyzing stress distribution and strain. In the simulation, the titanium alloy scaffold bore a maximum stress of 122.8626 MPa, while the centrally encapsulated HAp material delivered 27.92 MPa. The design demonstrated superior structural strength, thereby reducing stress concentration. The scaffold was manufactured using SLM, and the uniform design method was used to determine a collection of optimum annealing parameters. Nanoindentation and compression tests were used to determine the influence of annealing on the elastic modulus, hardness, and strain energy of the scaffold.Keywords
Funding Information
- ZuoYing Armed Forces General Hospital (KAFGH-ZY-A-112015)
This publication has 33 references indexed in Scilit:
- Multi-objective optimization for designing porous scaffolds with controllable mechanics and permeability: A case study on triply periodic minimal surface scaffoldsComposite Structures, 2024
- The role of stiffness-matching in avoiding stress shielding-induced bone loss and stress concentration-induced skeletal reconstruction device failureActa Biomaterialia, 2023
- Radial gradient design enabling additively manufactured low-modulus gyroid tantalum structuresInternational Journal of Mechanical Sciences, 2023
- Enhanced bone formation in locally-optimised, low-stiffness additive manufactured titanium implants: An in silico and in vivo tibial advancement studyActa Biomaterialia, 2022
- Influence of pore size of porous titanium fabricated by vacuum diffusion bonding of titanium meshes on cell penetration and bone ingrowthActa Biomaterialia, 2016
- 3D printed Ti6Al4V implant surface promotes bone maturation and retains a higher density of less aged osteocytes at the bone-implant interfaceActa Biomaterialia, 2016
- The use of a novel bone allograft wash process to generate a biocompatible, mechanically stable and osteoinductive biological scaffold for use in bone tissue engineeringJournal of Tissue Engineering and Regenerative Medicine, 2014
- The use of allograft shell with intramedullary vascularized fibula graft for intercalary reconstruction after diaphyseal resection for lower extremity bony malignancyJournal of Surgical Oncology, 2010
- Age, gender, and bone lamellae elastic moduliJournal of Orthopaedic Research, 2000
- Tissue reaction to three ceramics of porous and non‐porous structuresJournal of Biomedical Materials Research, 1972