Volumetry of Selected Brain Regions—Can We Compare MRI Examinations of Different Manufacturers and Field Strengths?
Authors:
Open Access
- 20 January 2025
- journal article
- research article
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 35 (2) , 363-378
Abstract
Purpose: Magnetic Resonance Imaging based brain segmentation and volumetry has become an important tool in clinical routine and research. However the impact of the used hardware is only barely investigated. This study aims to assess the influence of scanner manufacturer, field strength and head-coil on volumetry results. Methods: 10 healthy subjects (27.4 ± 1.71 years) were prospectively examined in a Philips Achieva 1.5T, Philips Ingenia CX 3T, Siemens MAGNETOM Aera 1.5T and Siemens MAGNETOM Vida 3T, the latter equipped with three different head coils, within one day. Brain volumetry of the whole brain, total white and grey matter, the cortical grey matter of the supratentorial lobes as well as regions important for the differentiation of neurodegenerative diseases of the dementia and movement disorder spectrum and the ventricular system was performed using the CE-certified software mdbrain by mediaire (Berlin, Germany). Both raw volumetry results and percentile allocation provided by the software were analysed. Results: This study reveals significantly different volumetry results for all examined brain regions beside the ventricular system between the different MRI devices but comparable results between the different head coils. When examining the percentile allocation provided by used software, the Intraclass-Correlation-Coefficient (ICC) values were even lower than the raw volume ICC values ranging from poor to excellent correlation. Conclusion: The present study reveals highly relevant results that need to be considered both in clinical routine when analysing follow-up examinations from different scanner types and clinical research, especially when planning longitudinal and/or multicentre studies.Keywords
Funding Information
- Universitätsklinikum Schleswig-Holstein – Campus Kiel
This publication has 24 references indexed in Scilit:
- Reliability of brain atrophy measurements in multiple sclerosis using MRI: an assessment of six freely available software packages for cross-sectional analysesNeuroradiology, 2023
- Characterization of B1+ field variation in brain at 3 T using 385 healthy individuals across the lifespanMagnetic Resonance in Medicine, 2021
- Effect of MRI acquisition acceleration via compressed sensing and parallel imaging on brain volumetryMagnetic Resonance Materials in Physics, Biology and Medicine, 2021
- Hippocampal subfield volumetry from structural isotropic 1 mm3MRI scans: A note of cautionHuman Brain Mapping, 2020
- Establishing intra‐ and inter‐vendor reproducibility of T1 relaxation time measurements with 3T MRIMagnetic Resonance in Medicine, 2018
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Clinical use of brain volumetryJournal of Magnetic Resonance Imaging, 2012
- Visual assessment of posterior atrophy development of a MRI rating scaleEuropean Radiology, 2011
- Intra- and interscanner variability of automated voxel-based volumetry based on a 3D probabilistic atlas of human cerebral structuresNeuroImage, 2010
- Gradient distortions in MRI: Characterizing and correcting for their effects on SIENA-generated measures of brain volume changeNeuroImage, 2010