Head size and dislocation rate in primary total hip arthroplasty
Authors:
Open Access
- 1 January 2013
- journal article
- research article
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 47 (5) , 443-8
Abstract
Background: Dislocation after total hip arthroplasty (THA) has a multifactorial etiology with variables such as surgical approach, component orientation and position, type of cup, stem and head size. Review of the literature regarding the relationship of head size and dislocation rate in THA is suggestive that large femoral head size is associated with lower dislocation rate after THA. However, limited data is available as a proof of this hypothesis. The purpose of this study was to determine that the use of large head size would lead to a decreased incidence of dislocations following THA. Materials and Methods: 317 primary THAs were performed using the posterolateral approach with posterior soft-tissue repair between January 2006 and December 2009. Cases were divided into two groups (A and B). Femoral head diameter size 36 mm was used in 163 THA in group A and 28 mm in 154 THA in group B. Average period of followup being 2 years (6 month to 4 years). Patients were routinely followed at definite intervals and were specifically assessed for dislocation. Results: One or more dislocations occurred in 11 out of 317 hips with the overall rate of dislocation being 3.47%. Dislocation rate was 0.6% in 36 mm head size and 6.49% with 28 mm head size (P value is 0.0107). Keeping the stem design variable as a constant, the difference in the rate of dislocation between the two groups was again found to be statistically significant for both un-cemented and cemented stem. Conclusion: Dislocation rate decreased significantly as the size of the head increased in primary THA. However, longer followup is necessary as rate of dislocation or in vivo highly cross linked poly failure or fracture may increase in future affecting the rate of dislocations in primary THA.Keywords
This publication has 25 references indexed in Scilit:
- Late Dislocation after Total Hip ArthroplastyClinical Medicine & Research, 2008
- Epidemiology of Dislocation after Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2006
- Effect of Femoral Head Diameter and Operative Approach on Risk of Dislocation After Primary Total Hip ArthroplastyJournal of Bone and Joint Surgery, 2005
- Epidemiology of instability after total hip replacementOrthopedic Clinics of North America, 2001
- Relationship of Femoral Head and Acetabular Size to the Prevalence of DislocationClinical Orthopaedics and Related Research, 1998
- Operative correction of an unstable total hip arthroplasty.Journal of Bone and Joint Surgery, 1992
- Dislocation in total hip arthroplasties.1980
- Postoperative Dislocation After Charnley Low-Friction ArthroplastyClinical Orthopaedics and Related Research, 1978
- Dislocation and Instability Complicating Low Friction Arthroplasty of the Hip JointClinical Orthopaedics and Related Research, 1976
- Range of Motion Studies for Total Hip ReplacementsClinical Orthopaedics and Related Research, 1975