Limited range of motion of hip resurfacing arthroplasty due to unfavorable ratio of prosthetic head size and femoral neck diameter
Open Access
- 1 January 2008
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 79 (6) , 748-754
Abstract
Background and purpose Hip resurfacing arthroplasty is being used more and more frequently. The small ratio in size between the resurfaced femoral head and the relatively thick femoral neck raises the question of whether the range of motion is sufficient, particularly with regard to the high mobility required by younger patients. We analyzed motion in a CAD model. Methods Three-dimensional CAD models of the natural hip were created from CT scans and 8 designs of hip resurfacing prostheses (head diameter between 42 mm and 54 mm combined with a hemispherical cup) were implanted in a virtual sense. We simulated 3 different leg positions and the range of motion was evaluated, considering five different implant positions. Results The range of motion of the hip resurfacing designs analyzed was far below the range of motion of stemmed total hip prostheses. None of the resurfacing prostheses provided flexion movements of 90° without impingement. The average range of motion of hip resurfacing arthroplasty was 31–48° below the range of motion of a stemmed total hip replacement with 32-mm head diameter. Interpretation The range of motion of the hip resurfacing designs examined was substantially less than that of a conventional total hip prosthesis. Since impingement of the femoral neck on the acetabular component increases the risk of neck fractures, of dislocation and of subsequent implant loosening, the design and position of the implant should be considered before using hip resurfacing arthroplasty as a standard treatment for younger patients.Keywords
This publication has 24 references indexed in Scilit:
- Noninvasive three‐dimensional assessment of femoroacetabular impingementJournal of Orthopaedic Research, 2006
- Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacementMedical Engineering & Physics, 2006
- Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplastyActa Orthopaedica, 2006
- Resurfacing hip prostheses revisitedInternational Orthopaedics, 2005
- Complications Associated with Hip Resurfacing ArthroplastyOrthopedic Clinics of North America, 2005
- Hydroxyapatite-Coated Femoral Implant in Metal-on-Metal Resurfacing Hip Arthroplasty: Minimum of Two Years Follow-UpOrthopedic Clinics of North America, 2005
- Biomechanics of Large Femoral HeadsClinical Orthopaedics and Related Research, 2004
- Methode zur Evaluierung von Einflußfaktoren auf die Luxationsstabilität von künstlichen Hüftgelenken / Method for the Evaluation of Factors Influencing the Dislocation Stability of Total Hip EndoprothesesBiomedical Engineering / Biomedizinische Technik, 2004
- Computergestützte Bewegungssimulation an Hüftendoprothesen mit Keramik-Keramik-Gleitpaarung. Analyse der Einflussparameter Implantat-Design und PositionZeitschrift für Orthopädie und ihre Grenzgebiete, 2002
- Treatment of hip instabilityOrthopedic Clinics of North America, 2001