Technical Note: More accurate and efficient segmentation of organs‐at‐risk in radiotherapy with convolutional neural networks cascades
Authors:
- 19 November 2018
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 46 (1) , 286-292
Abstract
Purpose: Manual delineation of organs‐at‐risk ( OAR s) in radiotherapy is both time‐consuming and subjective. Automated and more accurate segmentation is of the utmost importance in clinical application. The purpose of this study is to further improve the segmentation accuracy and efficiency with a novel network named convolutional neural networks ( CNN ) Cascades. Methods: CNN Cascades was a two‐step, coarse‐to‐fine approach that consisted of a simple region detector ( SRD ) and a fine segmentation unit ( FSU ). The SRD first used a relative shallow network to define the region of interest ( ROI ) where the organ was located, and then, the FSU took the smaller ROI as input and adopted a deep network for fine segmentation. The imaging data (14,651 slices) of 100 head‐and‐neck patients with segmentations were used for this study. The performance was compared with the state‐of‐the‐art single CNN in terms of accuracy with metrics of Dice similarity coefficient ( DSC ) and Hausdorff distance ( HD ) values. Results: The proposed CNN Cascades outperformed the single CNN on accuracy for each OAR . Similarly, for the average of all OAR s, it was also the best with mean DSC of 0.90 ( SRD : 0.86, FSU : 0.87, and U‐Net: 0.85) and the mean HD of 3.0 mm ( SRD : 4.0, FSU : 3.6, and U‐Net: 4.4). Meanwhile, the CNN Cascades reduced the mean segmentation time per patient by 48% ( FSU ) and 5% (U‐Net), respectively. Conclusions: The proposed two‐step network demonstrated superior performance by reducing the input region. This potentially can be an effective segmentation method that provides accurate and consistent delineation with reduced clinician interventions for clinical applications as well as for quality assurance of a multicenter clinical trial.Keywords
Funding Information
- National Cancer Institute
This publication has 31 references indexed in Scilit:
- The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information RepositoryJournal of Digital Imaging, 2013
- Atlas-based automatic segmentation of head and neck organs at risk and nodal target volumes: a clinical validationRadiation Oncology, 2013
- Variations in the Contouring of Organs at Risk: Test Case From a Patient With Oropharyngeal CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Auto‐segmentation of normal and target structures in head and neck CT images: A feature‐driven model‐based approachMedical Physics, 2011
- Intra-observer Variability of Organs at Risk for Head and Neck Cancer: Geometric and Dosimetric ConsequencesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Dosimetric Evaluation of Automatic Segmentation for Adaptive IMRT for Head-and-Neck CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Variability of Target and Normal Structure Delineation for Breast Cancer Radiotherapy: An RTOG Multi-Institutional and Multiobserver StudyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Evaluation of an atlas-based automatic segmentation software for the delineation of brain organs at risk in a radiation therapy clinical contextRadiotherapy and Oncology, 2008
- Realization of the Contrast Limited Adaptive Histogram Equalization (CLAHE) for Real-Time Image EnhancementJournal of Signal Processing Systems, 2004
- Comparing images using the Hausdorff distanceIEEE Transactions on Pattern Analysis and Machine Intelligence, 1993