Accuracy of Instrumented Mouthguards During Direct Jaw Impacts Seen in Boxing
Authors:
- 19 July 2024
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 52 (12) , 3219-3227
Abstract
Purpose Measuring head kinematics data is important to understand and develop methods and standards to mitigate head injuries in contact sports. Instrumented mouthguards (iMGs) have been developed to address coupling issues with previous sensors. Although validated with anthropomorphic test devices (ATDs), there is limited post-mortem human subjects (PMHS) data which provides more accurate soft tissue responses. This study evaluated two iMGs (Prevent Biometrics (PRE) and Diversified Technical Systems (DTS) in response to direct jaw impacts. Methods Three unembalmed male cadaver heads were properly fitted with two different boil-and-bite iMGs and impacted with hook (4 m/s) and uppercut (3 m/s) punches. A reference sensor (REF) was rigidly attached to the base of the skull, impact kinematics were transformed to the head center of gravity and linear and angular kinematic data were compared to the iMGs including Peak Linear Acceleration, Peak Angular Acceleration, Peak Angular Velocity, Head Injury Criterion (HIC), HIC duration, and Brain Injury Criterion. Results Compared to the REF sensor, the PRE iMG underpredicted most of the kinematic data with slopes of the validation regression line between 0.72 and 1.04 and the DTS overpredicted all the kinematic data with slopes of the regression line between 1.4 and 8.7. Conclusion While the PRE iMG was closer to the REF sensor compared to the DTS iMG, the results did not support the previous findings reported with use of ATDs. Hence, our study highlights the benefits of using PMHS for validating the accuracy of iMGs since they closely mimic the human body compared to any ATD’s mandible.Keywords
Funding Information
- Wayne State University
This publication has 29 references indexed in Scilit:
- Biofidelity and Limitations of Instrumented Mouthguard Systems for Assessment of Rigid Body Head KinematicsAnnals of Biomedical Engineering, 2024
- Consensus Head Acceleration Measurement Practices (CHAMP): Laboratory Validation of Wearable Head Kinematic DevicesAnnals of Biomedical Engineering, 2022
- Development of a Low-Power Instrumented Mouthpiece for Directly Measuring Head Acceleration in American FootballAnnals of Biomedical Engineering, 2021
- A Two-Phased Approach to Quantifying Head Impact Sensor Accuracy: In-Laboratory and On-Field AssessmentsAnnals of Biomedical Engineering, 2020
- Validation and Comparison of Instrumented Mouthguards for Measuring Head Kinematics and Assessing Brain Deformation in Football ImpactsAnnals of Biomedical Engineering, 2020
- Development, Validation and Pilot Field Deployment of a Custom Mouthpiece for Head Impact MeasurementAnnals of Biomedical Engineering, 2019
- In Vivo Evaluation of Wearable Head Impact SensorsAnnals of Biomedical Engineering, 2015
- A Headform for Testing Helmet and Mouthguard Sensors that Measure Head Impact Severity in Football PlayersAnnals of Biomedical Engineering, 2014
- An Instrumented Mouthguard for Measuring Linear and Angular Head Impact Kinematics in American FootballAnnals of Biomedical Engineering, 2013
- Physiologically based models for bone-seeking elementsToxicology and Applied Pharmacology, 1991