Seismic Performance of Hybrid Columns of Concrete-Filled Square Steel Tube with FRP-Confined Concrete Core
- 1 August 2018
- journal article
- research article
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 22 (4)
Abstract
An experimental program that investigated the seismic performance of concrete-filled square steel tube with fiber-reinforced polymer (FRP)–confined concrete core (FCCC) column (SCFC) was conducted. Fourteen SCFC specimens were fabricated with four parameters of axial compression ratio, strength grade of concrete, thickness of FRP tube, and thickness of steel tube and tested under constant axial compression and reversed-cyclic lateral loading. Examinations of the test data resulted a number of significant conclusions with regard to the influence of the investigated column parameters on the performance of SCFC columns. Of primary importance, SCFC columns exhibit favorable energy dissipation and ductility, even when the columns were subjected to high axial loads. The results also indicate that SCFC columns delivered satisfactory lateral moment-bearing capacity and displacement ductility under high axial compression ratio. In addition, a good level of average stiffness and equivalent viscous damping ratio were examined. Furthermore, the variations of hoop strains along column height, the relationship of axial displacement–lateral drift ratio, and the plastic hinge length were examined to evaluate the seismic performance of SCFC columns.Keywords
This publication has 37 references indexed in Scilit:
- A comparative analysis of energy dissipation and equivalent viscous damping of RC columns subjected to uniaxial and biaxial loadingEngineering Structures, 2012
- Hybrid FRP–concrete–steel tubular columns: Concept and behaviorConstruction and Building Materials, 2007
- Behaviour of concrete-filled double skin rectangular steel tubular beam–columnsJournal of Constructional Steel Research, 2006
- EQUIVALENT VISCOUS DAMPING EQUATIONS FOR DIRECT DISPLACEMENT BASED DESIGNJournal of Earthquake Engineering, 2005
- Behaviour of concrete-filled double skin (CHS inner and CHS outer) steel tubular stub columns and beam-columnsJournal of Constructional Steel Research, 2004
- Use of FRP composites in civil structural applicationsConstruction and Building Materials, 2003
- Seismic performance of steel beams to concrete-filled steel tubular column connectionsJournal of Constructional Steel Research, 2003
- Composite damping ratio of seismically isolated regular bridgesEngineering Structures, 1997
- FRP-encased concrete as a structural materialMagazine of Concrete Research, 1982
- ULTIMATE LOAD DESIGN OF CONCRETE STRUCTURES.Proceedings of the Institution of Civil Engineers, 1962