Effect of Partial Pressure of Hydrogen on IGSCC of Alloy 600 in PWR Primary Water
Authors:
- R.B. RebakRRR.B. Rebak
- 1 October 1991
- journal article
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 47 (10) , 754-757
Abstract
The frequently reported effect of the partial pressure of hydrogen on the alloy 600 susceptibility to intergranular stress corrosion cracking (IGSCC) in high-temperature water is explained in this paper. On the basis of thermodynamic calculations, it was demonstrated that the susceptibility of alloy 600 to IGSCC is connected with the stability of NiO in this environment. The lower the free energy of formation of NiO, the higher the susceptibility of alloy 600 to IGSCC.Keywords
This publication has 8 references indexed in Scilit:
- Aftereffects Produced in Alloy 600 by Exposure to Lithiated High-Temperature WaterCorrosion, 1991
- Effect of Heat Treatment on the Behavior of Alloy 600 in Lithiated Water Containing Dissolved Hydrogen at 25 to 350°CCorrosion, 1991
- A mechanism for hydrogen-induced intergranular stress corrosion cracking in alloy 600Metallurgical Transactions A, 1990
- Temperature Effects on Alloy 600 PWSCC from 310 to 330 C (590 to 626 F)1989
- IGSCC Behavior of Alloy 600 Steam Generator Tubing in Water or Steam Tests Above 360 CCorrosion, 1987
- Effect of Hydrogen on the Intergranular Stress Corrosion Cracking of Alloy 600 in High Temperature Aqueous EnvironmentsCorrosion, 1987
- Nature of the Corrosion Reaction at the Anodic Oxide Film on Titanium in HCl SolutionsCorrosion, 1984
- Solubilities of Inert Gases in Water. 0° C. to Near the Critical Point of Water.Journal of Chemical & Engineering Data, 1960