Abstract
Objectives: To explore our initial experience with real time three‐dimensional transesophageal echocardiography (RT3DTEE) for the assessment of prosthetic valves (PV).Methods: The study included 40 patients (mean age 35 ± 8.5 years, 68% male) who underwent PV implant. Fifty PV (34 bioprosthetic and 16 mechanical) were evaluated using two‐dimensional (2D)TEE and RT3DTEE to rule out PV dysfunction.Results: In all patients, RT3DTEE allowed good and simultaneous visualization of PV leaflets. Ten patients had normal functioning PV (5 in mitral, 3 in aortic, and 2 in tricuspid positions). Infective endocarditis was evident in 13 patients (20 PV) by repeated 2DTEE. RT3DTEE confirmed the 2DTEE diagnosis of endocarditis in same patients. Clear delineation of vegetations (size, site, and number) was obtained from RT3DTEE full volume while the vegetation attachment, consistency, mobility and its relation to valve structure were obtained using zoom 3D. Paraaortic abscesses size, site, extension, wall thickness of the abscess could be identified by RT3DTEE in 7 PV. Through cropping of the full‐volume 3D images, the orifice of communication between the abscess cavity and aorta could be visualized well in en face view. Color full‐volume allowed the detection of paravalvular regurgitation (size, location, direction, and extent) in 8 patients. In the 18 PV who underwent redo surgery, the intra‐operative findings confirmed the RT3DTEE description of PV lesions.Conclusion: Real time 3DTEE improved the anatomical and functional assessment of PV with better understanding of the underlying causes of PV dysfunction; hence, it could improve the management planning for such patients.Keywords
This publication has 20 references indexed in Scilit:
- Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal EchocardiographyJournal of Cardiovascular Ultrasound, 2012
- Real-Time Three-Dimensional Transesophageal Echocardiography Is Useful for the Localization of a Small Mitral Paravalvular LeakThe Annals of Thoracic Surgery, 2011
- Usefulness of Live/Real Time Three‐Dimensional Transthoracic Echocardiography in Evaluation of Prosthetic Valve FunctionEchocardiography, 2009
- The Value of Live/Real Time Three‐Dimensional Transesophageal Echocardiography in the Assessment of Valvular VegetationsEchocardiography, 2009
- Usefulness of real-time three-dimensional echocardiography for diagnosis of infective endocarditisScandinavian Cardiovascular Journal, 2009
- 2008 Focused Update Incorporated Into the ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart DiseaseCirculation, 2008
- Thrombosis of prosthetic heart valves: diagnosis and therapeutic considerationsHeart, 2006
- Feasibility and Diagnostic Accuracy of Quantitative Assessment of Mechanical Prostheses Leaflet Motion by Transthoracic and Transesophageal Echocardiography in Suspected Prosthetic Valve DysfunctionThe American Journal of Cardiology, 2006
- Echocardiographic assessment of artificial heart valves: British Society of Echocardiography position paperHeart, 1994
- Comparison of transthoracic and transesophageal echocardiography for detection of abnormalities of prosthetic and bioprosthetic valves in the mitral and aortic positionsThe American Journal of Cardiology, 1993