The Influence of Equipment Design and Process Parameters on Granule Breakage in a Semi-Continuous Fluid Bed Dryer after Continuous Twin-Screw Wet Granulation
Open Access
- 23 February 2021
- journal article
- research article
- Published by MDPI AG in Pharmaceutics
- Vol. 13 (2) , 293
Abstract
The drying unit of a continuous from-powder-to-tablet manufacturing line based on twin-screw granulation (TSG) is a crucial intermediate process step to achieve the desired tablet quality. Understanding the size reduction of pharmaceutical granules before, during, and after the fluid bed drying process is, however, still lacking. A first major goal was to investigate the breakage and attrition phenomena during transport of wet and dry granules, the filling phase, and drying phase on a ConsiGma-25 system (C25). Pneumatic transport of the wet granules after TSG towards the dryer induced extensive breakage, whereas the turbulent filling and drying phase of the drying cells caused rather moderate breakage and attrition. Subsequently, the dry transfer line was responsible for additional extensive breakage and attrition. The second major goal was to compare the influence of drying air temperature and drying time on granule size and moisture content for granules processed with a commercial-scale ConsiGma-25 system and with the R&D-scale ConsiGma-1 (C1) system. Generally, the granule quality obtained after drying with C1 was not predictive for the C25, making it challenging during process development with the C1 to obtain representative granules for the C25.Keywords
Funding Information
- Bayer (N/A)
This publication has 33 references indexed in Scilit:
- Moisture and drug solid-state monitoring during a continuous drying process using empirical and mass balance modelsEuropean Journal of Pharmaceutics and Biopharmaceutics, 2014
- Influence of raw material properties upon critical quality attributes of continuously produced granules and tabletsEuropean Journal of Pharmaceutics and Biopharmaceutics, 2014
- Stability and repeatability of a continuous twin screw granulation and drying systemEuropean Journal of Pharmaceutics and Biopharmaceutics, 2013
- Granulation rate processes in the kneading elements of a twin screw granulatorAIChE Journal, 2013
- Twin screw granulation: Steps in granule growthInternational Journal of Pharmaceutics, 2012
- Continuous twin screw granulation: Influence of process variables on granule and tablet qualityEuropean Journal of Pharmaceutics and Biopharmaceutics, 2012
- Real-time assessment of critical quality attributes of a continuous granulation processPharmaceutical Development and Technology, 2011
- Inline Real-Time Near-Infrared Granule Moisture Measurements of a Continuous Granulation–Drying–Milling ProcessAAPS PharmSciTech, 2011
- Continuous granulation in the pharmaceutical industryChemical Engineering Science, 2005
- Kinetics of droplet evaporationChemical Engineering Science, 1991