High Incidence of Intramural Thrombus After Overlapping Paclitaxel-Eluting Stent Implantation
Authors:
- 1 August 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 1 (1) , 28-35
Abstract
Systematic analysis of in vivo angioscopy and postmortem histopathology for paclitaxel-eluting stents (PES) has not been previously reported. We assessed 1-month angioscopic and histopathologic sequelae of overlapping PES in pig coronary arteries. Overlapping PES and bare-metal stents (BMS; n=9, one pair per pig) were implanted, and animals were euthanized at 1 month. Late lumen loss was reduced in PES compared with BMS (0.46+/-0.63 mm versus 1.30+/-0.50 mm; P=0.01). Angioscopically, PES stent struts were clearly visible and accompanied by substantial red material indicating mural thrombi. In contrast, stent struts and mural thrombi were barely visible in BMS (P<0.001 versus PES). Macroscopically, mural thrombi were abundant but distributed irregularly throughout the PES, with greater concentration in overlapping segments. Only occasional mural thrombi were noted for BMS. Microscopically, neointima of BMS was fibrocellular and mature, whereas only a thin layer of immature neointima was seen in PES. Neointimal thickness was less in PES than BMS (0.11+/-0.07 mm versus 0.33+/-0.12 mm; P=0.018). Additionally, extensive para-strut and intramural thrombi, red blood cell debris, and minute luminal thrombi were observed in PES. Despite normal angioscopic appearance of both proximal and distal nonstented reference segments, endothelium-dependent relaxation to substance P was notably diminished (PES, 0+/-7% versus BMS, 10+/-6%; P=0.007), whereas nitroglycerin response was preserved (PES, 9+/-5% versus BMS, 12+/-7%; P=0.34). In the porcine coronary model, overlapping PES is associated with marked intramural thrombi, which was accurately detected on angioscopy at 1 month. Moreover, despite normal luminal angioscopic appearance, adjacent nonstented reference segments demonstrated impaired endothelium-dependent vasoreactivity.Keywords
This publication has 29 references indexed in Scilit:
- Six-Month Comparison of Coronary Endothelial Dysfunction Associated With Sirolimus-Eluting Stent Versus Paclitaxel-Eluting StentJACC: Cardiovascular Interventions, 2008
- Overlapping paclitaxel-eluting stents: Long-term effects in a porcine coronary artery modelCardiovascular Research, 2007
- Serial long-term evaluation of neointimal stent coverage and thrombus after sirolimus-eluting stent implantation by use of coronary angioscopyHeart, 2007
- Serial Angioscopic Evidence of Incomplete Neointimal Coverage After Sirolimus-Eluting Stent ImplantationCirculation, 2007
- Local vascular dysfunction after coronary paclitaxel-eluting stent implantationInternational Journal of Cardiology, 2007
- Pathology of Drug-Eluting Stents in HumansJACC, 2006
- Correlates and Long-Term Outcomes of Angiographically Proven Stent Thrombosis With Sirolimus- and Paclitaxel-Eluting StentsCirculation, 2006
- Indication of long-term endothelial dysfunction after sirolimus-eluting stent implantationEuropean Heart Journal, 2005
- Differential Response of Delayed Healing and Persistent Inflammation at Sites of Overlapping Sirolimus- or Paclitaxel-Eluting StentsCirculation, 2005
- Angioscopic evaluation of incompletely obstructing coronary intraluminal filling defects: Comparison to angiographyCatheterization and Cardiovascular Diagnosis, 1994